Tektronix Waveform Monitors WFM700 Series User Manual

Page 54

Advertising
background image

Reference

WFM700 Series Waveform Monitors User Manual

3- 5

Table 3- 1: DID and SDID values for common ancillary data types

Ancillary data type

DID value

SDID value

ARIB TR-B22, Sub Information of transmitting materials

0x5F

0xE0

ARIB TR-B23, Line 20 User Data -- 1

0x5F

0xFC

ARIB TR-B23, Line 20 User Data -- 2

0x5F

0xFB

Video Payload Identifier

0x41

0x01

ARIB STD-B35 Trigger Signal for Data Broadcasting

0x5F

0xFD

ARIB STD-B37 Closed Captioning

Analog signal
SD signal
HD signal

0x5F
0x5F
0x5F

0xDD
0xDE
0xDF

ARIB STD-B39 Inter Stationary Control Data

ARIB specification
ITU specification

0x5F
0x43

0xFE
0x01

SMPTE RP-188 Time Code

0x60

None

EIA-608 Closed Captioning

0x61

0x02

EIA-708 Closed Captioning

0x61

0x01

Program Description

0x62

0x01

AES Audio Group 1

0xFF

None

SD Embedded Audio

Group 1
Group 2
Group 3
Group 4

0xFF
0xFD
0xFB
0xF9

None
None
None
None

SD Extended Audio Packets

Group 1
Group 2
Group 3
Group 4

0xFE
0xFC
0xFA
0xF8

None
None
None
None

HD Embedded Audio

Group 1
Group 2
Group 3
Group 4

0xE7
0xE6
0xE5
0xE4

None
None
None
None