Reference
WFM700 Series Waveform Monitors User Manual
3- 5
Table 3- 1: DID and SDID values for common ancillary data types
Ancillary data type
DID value
SDID value
ARIB TR-B22, Sub Information of transmitting materials
0x5F
0xE0
ARIB TR-B23, Line 20 User Data -- 1
0x5F
0xFC
ARIB TR-B23, Line 20 User Data -- 2
0x5F
0xFB
Video Payload Identifier
0x41
0x01
ARIB STD-B35 Trigger Signal for Data Broadcasting
0x5F
0xFD
ARIB STD-B37 Closed Captioning
Analog signal
SD signal
HD signal
0x5F
0x5F
0x5F
0xDD
0xDE
0xDF
ARIB STD-B39 Inter Stationary Control Data
ARIB specification
ITU specification
0x5F
0x43
0xFE
0x01
SMPTE RP-188 Time Code
0x60
None
EIA-608 Closed Captioning
0x61
0x02
EIA-708 Closed Captioning
0x61
0x01
Program Description
0x62
0x01
AES Audio Group 1
0xFF
None
SD Embedded Audio
Group 1
Group 2
Group 3
Group 4
0xFF
0xFD
0xFB
0xF9
None
None
None
None
SD Extended Audio Packets
Group 1
Group 2
Group 3
Group 4
0xFE
0xFC
0xFA
0xF8
None
None
None
None
HD Embedded Audio
Group 1
Group 2
Group 3
Group 4
0xE7
0xE6
0xE5
0xE4
None
None
None
None