Lighting and operating instructions, For your safety read before lighting, Lighting instructions – Temco Tool 33TDVDSN User Manual

Page 24

Advertising
background image

24

TDVDSN Series Direct Vent Gas Fireplace

20007890

1. STOP! Read the safety information above.
2. Set the thermostat, if used, to the lowest set-

ting.

3. Turn off electric power to the appliance.
4. This appliance is equipped with an ignition

device which automatically lights the burner. Do
not try to light the burner by hand.

FOR YOUR SAFETY READ BEFORE LIGHTING

If you cannot reach your gas supplier, call
the Fire Department

C. Use only the wall switch or remote control switch

to turn the gas control on/off. Never use tools. If
the knob will not push in or turn by hand, do not
try to repair it, call a qualified service technician.
Applying force or any attempted repair may result
in a fire or explosion.

D. Do not use this fireplace if any part has been

under water. Immediately call a qualified service
technician to inspect the heater and to replace
any part of the control system and any gas con-
trol which has been under water.

A. This heater has a pilot which must be lit manu-

ally. When lighting the pilot follow these instruc-
tions exactly.

B. BEFORE LIGHTING smell all around the heater

area for gas. Be sure to smell next to the floor
because some gas is heavier than air and will
settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any fireplace

Do not touch any electric switch

Do not use any phone in your building

Immediately call your gas supplier from a
neighbor’s phone. Follow the gas supplier’s
instructions.

To Turn Off Gas to Heater

Lighting and Operating Instructions

1. Set thermostat to lowest setting.
2. Turn off all electric power to the appliance if

service is to be performed.

Lighting Instructions

WARNING:If you do not follow these instructions exactly, a fire or explosion

may result causing property damage, personal injury or loss of life.

ON

OFF

T209

electronic gas

control on/off

1/04

5. Open the access door located at the bottom of

the appliance to expose the controls.

6. Turn gas line valve to “ON”. (Fig. 38)
7. Wait five (5) minutes to clear out any gas, then

smell for gas, including near the floor. If you
smell gas, STOP! Follow “B” in the safety infor-
mation above. If you do not smell gas, go to the
next step.

8. Replace control access panel.
9. Turn on all electric power to the appliance.
10. Set thermostat to desired setting (if available).
11. If the appliance will not operate, follow the in-

structions “To Turn OFF Gas to Appliance” and
call your service technician or gas supplier.

3. Open the control access door.
4. Turn gas line valve to the “OFF” position.
5. Close the control access door.

Fig. 38