Tdvdsn series direct vent gas fireplace, Locating your fireplace, Mantels – Temco Tool 33TDVDSN User Manual

Page 6: Clearance to combustibles, Mantel chart

Advertising
background image

6

TDVDSN Series Direct Vent Gas Fireplace

20007890

Locating Your Fireplace

A - Flat on wall

B - Cross corner

C - **Island

D - Room divider

E - Flat on wall corner

F - Chase installation

Y - Refer to “Clearance to Combustibles” Section

Note (Fig. 2):
** Island (C) and Room Divider (D) installation is possible as
long as the horizontal portion of the vent system (X) does not
exceed 20’ (6 m). See details in manual Venting Section.

Fig. 2 Locate gas fireplace.

LU584-T

Y

E

A

B

C

D

F

Y

B

X

LU584-T

Locating unit

12/18/02 djt

X

Top of Unit to Ceiling ............................... 36” (914 mm)
Front of Unit to Combustibles .................. 36” (914 mm)
Appliance

Top .......................................................... 0” (0 mm)

Bottom ..................................................... 0” (0 mm)

Side ......................................................... 0” (0 mm)

Back ........................................................ 0” (0 mm)

Venting
Concentric sections of DV Vent

Top, bottom & sides .............................. 1” (25 mm)

Flex Vent .................................................. 7/8” (22 mm)

Mantels

The height that a combustible mantel is fitted above the
fireplace is dependent on the depth of the mantel. This
also applies to the distance between the mantel leg (if
fitted) and the fireplace.
For the correct mounting height and widths refer to
Figures 3a and 3b.
The fitting of a bay window trim kit does not effect
the distances and reference points referred to in the
diagram and chart.
Noncombustible mantels and legs may be installed at
any height and width around the appliance.
When using paint or lacquer to finish the mantel, such
paint or lacquer must be heat resistant to prevent
discoloration.

Clearance to Combustibles

A

B C

D E

V

W

X

Y

Z

Fireplace

CFM146

DV Mantel Chart

7/5/01 sta

CFM146

Fig. 3a Combustible mantel minimum installation.

Top Louvre

Assembly

Top of

Combustion

Chamber

Bottom of Door Trim

Mantel Shelf

Mantel from Top

Ref. or Breast Plate Ref.

of Combustion Chamber

Depth

36/39/TDVDSN

33TDVDSN

V

10” (254 mm)

A

19” (483 mm)

17” (432 mm)

W

8” (203 mm)

B

17” (432 mm)

15” (381 mm)

X

6” (152 mm)

C

15” (381 mm)

13” (330 mm)

Y

4” (101 mm)

D

13” (330 mm)

11” (279 mm)

Z

2” (51 mm)

E

11” (279 mm)

9” (229 mm)

Mantel Chart

J

F

G

H

I

Mantel

Leg

CFM164a

Mantel Leg Chart

06/22/01 sta

Mantel

Mantel Leg from Side

Ref.

Leg Depth

Ref.

of Comb. Opening

F

10” (254 mm)

K

11¹⁄₂” (292 mm)

G

8” (203 mm)

L

9¹⁄₂” (241 mm)

H

6” (152 mm)

M

7¹⁄₂” (191 mm)

I

4” (101 mm)

N

5¹⁄₂” (140 mm)

J

2” (51 mm)

O

3¹⁄₂” (89 mm)

Fig. 3b Combustible mantel leg minimum installation.

CFM170

Black

Surround

Face

CFM170

DV Builder Front

View

O

N

M

L

K

Side of

Combustion Chamber

Advertising