Temco Tool 33TDVDSN User Manual

Page 7

Advertising
background image

7

TDVDSN Series Direct Vent Gas Fireplace

20007890

A hearth is not mandatory but is recommended for
aesthetic purposes. We recommend a noncombustible
hearth which projects out 12” (305 mm) or more from
the front of the fireplace.

Cold climate installation recommendation:

When installing this unit against a non-
insulated exterior wall or chase, it is
mandatory that the outer walls be insulated
to conform to applicable insulation codes.

NOTE: Never allow vapor barrier to contact the
outer casing of this fireplace or venting.

Hearth

Noncombustible materials such as brick or tile may be
extended over the edges of the face of the appliance.
DO NOT cover any vent or grille panels.
If a Trim Kit is going to be installed on the fireplace, the
brick or tile will have to be installed flush with the edges
of the appliance.

Final Finishing

Framing and Finishing

1. Choose the unit location.
2. Place the unit into position and secure it to the floor

with 1¹⁄₂” (38 mm) screws, or nails. The holes to
secure the unit to the floor are located just behind
the access door grille on the left and right side of the
unit.

3. Frame in the fireplace with a header across the top.

It is important to allow for the finished wall face when
setting the depth of the frame.

4. Attach the fireplace to the frame using the adjust-

able frame drywall strips (located behind the access
door for shipping). Preset the depth to suit the facing
material of the wall. The strips are adjustable to 1/2”
(13 mm), 5/8” (16 mm) or 3/4” (19 mm). (Fig. 4)

5. Screw through the slotted holes in the drywall strip

and into the pre-drilled holes in the fireplace side.
Measure from the face of the fireplace to the face of
the drywall strip to confirm the final depth.

High Elevations

Input ratings are shown in BTU per hour and are
certified without deration for elevations up to
4,500 feet (1,370m) above sea level.
For elevations above 4,500 feet (1,370m) in USA,
installations must be in accordance with the cur-
rent ANSI Z223.1/NFPA 54 and/or local codes hav-
ing jurisdiction.
In Canada, please consult provincial and/or local
authorities having jurisdiction for installations at
elevations above 4,500 feet (1,370m).

Natural

LP (Propane)

Inlet Minimum

4.5” w.c.

10.8” w.c.

Inlet Maximum

14.0” w.c.

14.0” w.c.

Manifold Pressure

3.5” w.c.

10.0” w.c.

Gas Inlet and Manifold Pressures

FP1023

side nailing flange

1/27/00 djt

C

A

B

Fig. 4 Nailing flanges.

FP1023

Adjustable

1/2”, 5/8” &

3/4” Spacing

Adjustable Drywall Strip

(Nailing Flange)

Screw

Drywall

Position

Depths

A

1/2” / 13 mm

B

5/8” / 16 mm

C

3/4” / 19 mm

Gas Specifications

Max.

Min.

Input

Input

Model

Fuel

Gas Control BTU/h BTU/h

33TDVN

Nat

Millivolt

18,000 12,500

33TDVP

Prop

Millivolt

18,000 12,500

33TDVDSN Nat

120 V

18,000 n/a

33TDVDSP Prop

120 V

18,000 n/a

36TDVN

Nat

Millivolt

20,000 13,000

36TDVP

Prop

Millivolt

20,000 13,000

36TDVDSN Nat

120 V

20,000 n/a

36TDVDSP Prop

120 V

20,000 n/a

39TDVN

Nat

Millivolt

22,000 15,000

39TDVP

Prop

Millivolt

22,000 16,000

39TDVDSN Nat

120 V

22,000 n/a

39TDVDSP Prop

120 V

22,000 n/a