Temco Tool 33TDVDSN User Manual

Page 27

Advertising
background image

27

TDVDSN Series Direct Vent Gas Fireplace

20007890

Kit Number

Conversion Parts Included with Kit

20007864

20007891

20007903

Main Burner Orifice - LP

76776

20007908

20007907

Label, Conversion

10002876

10002876

10002876

Gas Supply Pressure (inches w.c.)

Minimum

Normal Maximum

LP (Propane)

10.8

11.0

14.0

Manifold Pressure (inches w.c.)

Normal

LP (Propane)

10.0”

Valve Conversion

1. Remove plastic cap from regulator fitting. (Fig. 44

) Unscrew fitting using a 7/16” wrench. Turn fitting
over so end of fitting marked “LPG” (red) screws into
valve. Tighten fitting (snug only). Replace plastic
cap.

2. Loosen screw and attach a manometer or pressure

gauge to the outlet pressure test port of the control
valve.

3. Turn on the gas supply. Turn on the electrical sup-

ply to the appliance. Check for gas leaks using soap
and water solution or leak detection solution. Bub-
bles indicate a leak that MUST be corrected. Do not
use an open flame to test for gas leaks.

4. Relight the main burners and verify proper burner

ignition and operation.

5. Check the air shutter opening for the corresponding

gas used.

6. With the main burner burning, read the pressure on

the manometer or pressure gauge. The pressure on
the gauge should read between 9.8” and 10.2” w.c.

7. Turn off the gas supply. Turn off the electrical supply

to the appliance.

8. Remove the manometer or pressure gauge. Tighten

the screw in the pressure tap.

9. Turn on the gas supply. Turn on the electrical supply

to the appliance.

10. Immediately test all gas line connections and the

control valve for gas leaks using a soap and water
solution or other gas detection solution. Bubbles
indicate a leak that MUST be corrected. Do not use
an open flame to test for gas leaks.

11. Using a ball point pen, fill out the conversion label

that is supplied with the conversion kit. Place the
conversion label adjacent to the rating plate.

Max. Input

33TDVDSP

18,000

36TDVDSP

20,000

39TDVDSP

22,000

1

2

3

4

T210

White-rodgers

gas control valve

1/04 djt

T210

Regulator

Fitting

Fig. 44 White-Rodgers 25M18A-706PI gas control.

Advertising