Texas Instruments MSP50C6xx User Manual

Page 123

Advertising
background image

Instruction Classification

4-37

Assembly Language Instructions

Table 4–27. Class 5 Instruction Description (Continued)

C5

Mnemonic

Description

0 1 0 1

1

MOV {adrs}, TOS

Store the contents of the top of stack (TOS) register to the data memory
location referred by addressing mode {adrs}. Transfer status is modified.

0 1 1 0

0

STAG {adrs}

Store 1 to the 17

th

bit of data memory location referred by {adrs}. Set the

tag bit.

0 1 1 0

1

RTAG {adrs}

Store 0 to the 17

th

bit of data memory location referred by {adrs}. Clear

the tag bit.

0 1 1 1 n–1

MOVT {adrs}, TFn

Store TF1 bit if n=1, TF2 bit if n=0 status bit to 17

th

bit of data memory

location referred by addressing mode {adrs}.

1 0 0 0

0

MOV SV, {adrs}

4

Load shift value (SV) register with contents of the location referred by ad-
dressing mode {adrs}. Transfer status is modified.

1 0 0 0

1

MOV PH, {adrs}

Load Product High (PH) register with content of data memory location
value referred by addressing mode {adrs}. Transfer is status modified.

1 0 0 1

0

MOV TOS, {adrs}

Load top of stack (TOS) register with content of data memory location
referred by addressing mode {adrs}.

1 0 0 1

1

MOV STR, {adrs}

8

Load String (STR) register with content of data memory location referred
by addressing mode {adrs}. Only the lower 8 bits are loaded. Transfer
status modified.

1 0 1 n

n

MOV APn, {adrs}

Load lower 5 bits with content of data memory location referred by
addressing mode {adrs} to accumulator pointer (AP) register n. Transfer
status is modified (16-bit value).

1 1 0 0

0

MOV MR, {adrs}

Load Multiplier (MR) register with content of data memory location
referred by addressing mode {adrs} and set the multiplier signed mode
(UM=0 in STAT register). Transfer status is modified.

1 1 0 0

1

MOVU MR, {adrs}

Load Multiplier (MR) register with content of data memory location
referred by addressing mode {adrs} and set the multiplier unsigned mode
(UM=1 in STAT register). Transfer status is modified.

1 1 0 1

0

MULR {adrs}

Multiply MR register by content of data memory location referred by
addressing mode {adrs}, add 0x00008000 to the 32-bit product to
produce a rounding on the upper 16 bits. Store the upper rounded 16 bits
to the PH register. No status change.

1 1 0 1

1

MUL {adrs}

Multiply MR register by content of data memory location referred by
addressing mode {adrs} and store the most significant 16 bits of product
into the PH register. No status change.

1 1 1 0

0

RET

Return from subroutine. Load data memory location value addressed by
R7 (STACK) to program counter.

1 1 1 0

1

IRET

Return from interrupt routine. Load data memory location value ad-
dressed by R7 (STACK) to program counter.

† The entire 17 bit is encoded. See Table 4–26.

Advertising