3 sip settings – TANDBERG 7000 MXP User Manual

Page 192

Advertising
background image

D1335403_T7000_MXP_User_Manual

192

4.8.6.3 SIP Settings

Proxy Settings

To be able to make a call with an E.164 alias or user name, Proxy must be set to On and an
Outbound Proxy IP-address must be specified. Outbound Proxy uses alias to look up the far end
IP-address.


Use Proxy

On

The system will use Outbound Proxy for outgoing calls

Off

Outbound Proxy is not used


Proxy Address

The Proxy Address defines the Outbound Proxy IP-address.

Port

Set the desired Proxy port when not using the standard port 5060.

Registrar Settings

To call into the system with E.164 alias or user name the server on which the system alias should
be registered must be specified. Normally registrar is set to Same as Proxy, but if registered on
another server Use Registrar must be set to On and the address must be specified in Registrar
Address.

Use Registrar

On

Register URL / E.164 number for incoming calls

Off

Registrar is not used

Same as
Proxy

Use the same IP-address and Port as Proxy



Registrar Address

This is the Registrar IP-address.

Port

Advertising