4.8.9 Data Port


The system provides two standard RS232 serial ports to allow a computer to be connected for
data transfer and control purposes. Note that when connecting to a PC the connecting cable must
be a straight through RS232 cable.

Baud Rate, Parity, Databits and Stopbits

If you wish to connect a PC to Data port 1, you must ensure that the PC and the system are
identically configured. The available settings are:


Baud
Rate
Parity
Databits
Stopbits



1200, 2400, 4800, 9600, 19200, 38400, 57600, 115200
None, Odd, Even

7, 8

1, 2


The control interface provided by the data port supports a subset of the Hayes command set as
well as a comprehensive set of system specific commands. It maintains communication with the
data port

s command interpreter at all times. All features available from the hand-held remote

control can be accessed through the data port.


Data Port 2

Data port 2 is dedicated to the main camera and will not be available in standard configuration.
The Data Port 2 menu contains the same items as the Data Port 1 menu; Baud rate, Parity,
Databits, Stopbits except for the Mode, which has VISCA and Auto selections.Mode.

The system will automatically detect WAVE cameras. If you are using a camera supporting the
VISCA protocol, select Mode: VISCA.
If Mode is Auto and no camera is connected to the Data port 2, the Baudrate, Parity, Databits and
Stopbits settings will be enabled.