Toshiba PORTEGE M400 User Manual

Page 66

Advertising
background image

2 Troubleshooting

2.4 System board Troubleshooting

2-18

[CONFIDENTIAL]

PORTEGE M400 Maintenance Manual (960-541)

Check 3

The IRT checks the System board. When the IRT detects an error, the system stops
or an error message appears.

If error message (18) is displayed, go to the Keyboard Troubleshooting Procedures
in Section 2.7.

If error message (19), (20) or (21) is displayed, go to the 2.5” HDD
Troubleshooting Procedures in Section 2.6.

If error message (22) is displayed, go to the USB 3.5” FDD Troubleshooting
Procedures in Section 2.5.

If error message

RAID-0 is CRITICAL

or

RAID-1 is DEGRADE

is displayed,

go to the 2.5” HDD Troubleshooting Procedures in Section 2.6.

If any other error message is displayed, go to Procedure 2.

(1)PIT ERROR
(2)MEMORY REFRESH ERROR
(3)TIMER CH.2 OUT ERROR
(6)FIRST 64KB MEMORY ERROR
(7)FIRST 64KB MEMORY PARITY ERROR
(8)VRAM MEMORY ERROR
(9)SYSTEM MEMORY ERROR
(10)SYSTEM MEMORY PARITY ERROR
(11)EXTENDED MEMORY ERROR
(12)EXTENDED MEMORY PARITY ERROR
(13)DMA PAGE REGISTER ERROR
(14)DMAC #1 ERROR
(15)DMAC #2 ERROR
(16)PIC #1 ERROR
(17)PIC #2 ERROR
(18)KBC ERROR
(19)HDC ERROR
(20)Built-in HDD ERROR
(21)Select Bay HDD ERROR
(22)No FDD ERROR
(23)TIMER INTERRUPT ERROR
(24)RTC UPDATE ERROR

PCI Express error
PROTECTED MODE ERROR
CPU EXCEPTION ERROR
KEYBOARD ERROR
FDC ERROR
Exception ERROR
RAID-0 is CRITICAL
RAID-1 is DEGRADE

Advertising