Levels:

Composite: 1 Vpp, 75 ohm

S-Video (Y/C):

Y: 1 Vpp, 75 ohm

C (PAL): 0.3 Vpp, 75 ohm

C (NTSC): 0.28 Vpp, 75 ohm


VGA formats supported on 'DVI-I out':
SVGA (800x600) 75Hz
XGA (1024x768) 60Hz
WXGA (1280x768) 60Hz
HD720p (1280x720) 50,60 Hz


DVI and specifications:

DVI stands for Digital Video Interface, and is a form of video interface technology made to
maximize the quality of flat panel LCD monitors and high-end video graphics cards.

The TANDBERG codec contains a DVI-I plug that can transmit either digital DVI signals or
standard analog VGA signals, depending on what type of monitor is connected.

DVI Specifications
TANDBERG DVI-I follows the VESA Monitor Timing Standard v1.08, also knows as Display
Monitor Timing (DMT).

Analog

Horizontal
Frequency

Vertical
frequency

Pixel
Clock

800x600 @
75Hz

46.875kHz

75.00Hz

49.50MHz

1024x768
@ 60Hz

48.363kHz

60.004Hz

65.00MHz

Digital

800x600 @
75Hz

46.875kHz

75.00Hz

49.50MHz

1024x768
@ 60Hz

48.363kHz

60.004Hz

65.00MHz

DVI-I Video resolution supported in F1 and above


The resolution used when showing a PAL image like the WAVE II is:

800x600 @ 75Hz.


The resolution used when showing a NTSC image like the WAVE II is:

1024x768 @ 60Hz.


Supported DVI cables:
TANDBERG supports DVI-D Single-Link, DVI-A and DVI-I Single-Link format cables.