Installation

29

RT-SVX20A-E4

Standard drive

Oversize drive

Note : Data includes pressure drops for standard filters and wet coils

Standard drive

Oversize drive

Note : Data includes pressure drops for standard filters and wet coils

Table 34 - WSD 090 Available static pressure

External Static Pressure (Pa)

25

50

75

100

125

150

175

200

225

250

275

300

m

3

/h

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

kW

kW

4080

-

-

-

-

-

-

-

-

768

0.56

810

0.63

850

0.70

888

0.76

925

0.83

961

0.91

995

0.98

1027

1.06

4590

-

-

-

-

-

-

763

0.63

807

0.70

850

0.78

889

0.85

926

0.93

961

1.00

995

1.08

1027

1.15

1059

1.23

5100

-

-

-

-

770

0.71

810

0.78

849

0.86

890

0.95

929

1.03

967

1.12

1000

1.20

1034

1.28

1065

1.36

1095

1.45

5610

-

-

782

0.83

823

0.90

861

0.97

897

1.05

933

1.12

969

1.23

1006

1.33

1041

1.42

1074

1.52

1104

1.60

1134

1.70

6120

798

0.94

838

1.04

876

1.12

913

1.20

947

1.28

980

1.37

1013

1.47

1047

1.57

1080

1.67

1113

1.77

1144

1.88

1173

1.98

325

350

375

m

3

/h

kW

kW

kW

4080

1060

1.13

1091

1.21

1121

1.29

4590

1091

1.32

1121

1.40

1151

1.49

5100

1125

1.53

1154

1.62

1183

1.71

5610

1163

1.79

1191

1.88

1217

1.97

6120

1202

2.08

1229

2.17

1256

2.27

Fan

RPM

Fan

RPM

Fan

RPM

Fan

RPM

Fan

RPM

Table 35 - WSH 090 Available static pressure

External Static Pressure (Pa)

25

50

75

100

125

150

175

200

225

250

275

300

m

3

/h

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

RPM

kW

kW

kW

4080

-

-

-

-

-

-

787

0.57

831

0.64

870

0.70

908

0.76

944

0.84

980

0.92

1015

0.99

1051

1.07

1085

1.15

4590

-

-

753

0.59

792

0.65

839

0.72

882

0.80

922

0.88

958

0.95

992

1.02

1026

1.10

1058

1.18

1090

1.27

1122

1.36

5100

789

0.71

822

0.78

853

0.84

892

0.91

935

0.99

974

1.08

1011

1.18

1044

1.25

1076

1.33

1106

1.41

1136

1.49

1165

1.59

5610

862

0.93

892

1.01

921

1.08

951

1.15

988

1.22

1026

1.31

1062

1.42

1096

1.52

1129

1.61

1158

1.69

1187

1.78

1214

1.86

6120

934

1.20

963

1.28

990

1.35

1016

1.43

1045

1.51

1079

1.59

1115

1.69

1148

1.80

1180

1.91

1210

2.02

1239

2.12

1266

2.21

325

350

375

m

3

/h

kW

kW

kW

4080

1118

1.23

1152

1.31

1185

1.39

4590

1153

1.45

1185

1.53

1216

1.62

5100

1194

1.68

1223

1.78

1251

1.88

5610

1242

1.96

1269

2.06

1296

2.17

6120

1291

2.30

1317

2.39

1343

2.49

Fan

RPM

Fan

RPM

Fan

RPM

Fan