A. Before your new unit is connected to a power supply,

check the incoming voltage with a voltmeter. If

anything less than 100% of the rated voltage for

operation is noted, correct immediately.

B. All units are equipped with a service cord, and must

be powered at proper operating voltage at all times.

Refer to cabinet data plate for this voltage.

TRUE

requires that a sole circuit be dedicated

for the unit. Failure to do so voids warranty.

WARNING

Compressor warranties are void if compressor burns out due

to low voltage.
WARNING

Power supply cord ground should not be removed!
WARNING

Do not use electrical appliances inside the food storage

compartments of the appliances unless they are of the

type recommended by the manufacturer.

NOTE

To reference wiring diagram - Remove lower rear grill.

Wiring diagram is positioned on the inside cabinet wall.

ELECTRICAL INSTRUCTIONS

INSTALLATION / OPERATION INSTRUCTIONS

A. The compressor is ready to operate. Plug in the unit.
B. The temperature control is set at the No. 4 position

from the factory. Allow unit to function several

hours, completely cooling cabinet before changing

the control setting.

C. Excessive tampering with the control could lead to

service difficulties. Should it ever become necessary

to replace temperature control, be sure it is ordered

from your TRUE dealer or recommended service agent.

NOTE

If the unit is disconnected or shut off, wait five minutes

before starting again.
RECOMMENDATION

Before loading product we recommend you run your TRUE

unit empty for two to three days. This allows you to be sure

electrical wiring and installation are correct and no shipping

damage has occurred. Remember, our factory warranty does

not cover product loss!

REPLACEMENT PARTS

TRUE maintains a record of the cabinet serial number for

your unit. If at any time during the life of your display case, a

part is needed, you may obtain this part by furnishing the

model number and serial number to the company from

whom you purchased the cabinet. Call Toll-Free: (800)-424-

TRUE (Direct to Parts Department). (800)-325-6152 (U.S.A. &

Canada only) or call:

(636)-240-2400.

STARTUP

Serial Number

REMOTE UNITS (This section applies to remotes only!)
• Remote cabinets must be ordered as remote. We do not

recommend converting from a standard self contained to

remote system.

• All remote cabinets must be hard wired.
• No castors available.
• All remote cabinets come standard using 404A refrigerant.
• All remote units come standard with expansion valve,

liquid line solenoid, heated condensate pan, and defrost

timer when applicable.

• Contact TRUE Technical Service for BTU requirements.

• No wiring necessary between cabinet and condensing unit.
• All remote condensing units purchased from TRUE are

208/230 volts single phase.

If you have any questions regarding this section, please call

TRUE at 1-(800)-325-6152.