True Manufacturing Company TDC-47 User Manual

Page 13

Advertising
background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

11

11

TEMPERATURE CONTROL ADJUSTMENT FOR

HIGH ALTITUDE / DEFROST OPERATIONS

TEMPERATURE CONTROL:
(Temperature Control Adjustment For High Altitude Only!)

Temperature control is located at the back of the unit

next to the rear grill. A flat head screw driver will need to

be used when adjusting the temperature of the unit. (See

image 1).

TERMS:

Cut-out - Temperature sensed by the controller that

shuts the compressor off.
Cut-in - Temperature sensed by the controller that turns

the compressor on.

REQUIRED TOOLS:

• Phillips Head Screwdriver

• 5/64" or 2 mm Allen Wrench

• T-7 Torx Wrench

STEP 1

Unplug the cooler.

STEP 2

Remove the screws that secure the temperature control
to the inset box lower left side of the cabinet (when
facing the front of the cabinet)

STEP 3

Pull out gently from cabinet.

STEP 4

For high elevation installations, it may be necessary to
"warm-up" the set points. To make the adjustment, insert
the appropriate tool in each adjustment screw and turn
1/4 of a revolution clockwise (to the right). This
procedure will adjust both the cut-in and cut-out about
2°F warmer.

STEP 5

Make sure to reconnect the pink wire to the proper

spade terminal when reinstalling.

MANUAL DEFROST:
The unit will need to be manually defrosted. Unplug unit

until all frost is gone. The manual defrost frequency will

depend on the units usage, environment, and the

amount of frost.

NOTE

Remember to connect drain hose to a garden type hose that

is routed to a floor drain when manually defrosting unit.

If ice builds up on interior walls- (TDC Units Only)
A

. Remove product, unplug and roll unit so defrost plug

is above floor drain (or large flat pan).

B

. Remove plug and allow ice to melt and drain. Do not

scrape interior of cabinet to loosen ice, as this will

damage the cabinet. Allow cabinet to defrost with

power off.

C

.

When ice has melted wipe up and water left

in the freezer floor.

D

. Be sure to replace defrost plug before moving freezer

back in position.

E

.

Allow freezer to refrigerate and cycle before placing

wire baskets and product back into freezer.

INSTALLATION / OPERATION INSTRUCTIONS

Danfoss Temperature Control (High Altitude Adjustment Only!)

Cut-out Adjustment Screw Allen (5/64"
or 2 mm) (clockwise for warmer)

Cut-in Adjustment Screw Torx (T-7)
(clockwise for warmer)

Compressor Connection

Compressor Connection
(double terminal)

Temperature
Control

1

2

Advertising