OPTIONAL DIPWELL FOR TDC MODELS

(Installing Dipwell):
TRUE

Dipping Cabinets come standard with pre-installed riv-nut holes to

attach an optional dipwell. There are multiple riv-nut holes for dipwell

locations on the cabinet. Locate which area you want the dipwell installed

then proceed with the directions below. (See image 1).

A

. Remove the dipwell backplate from one of two boxes that contain

the dipper well assembly.

B

. Two Phillips pan head machine screws are provided in the kit to

mount the backplate to the cabinet with the Inlet Tube Clip and

Inlet Tube. (See image 2 and illustration 1).

C

. After attaching the dipwell bowl to the backplate connect

the drain tube to the bowl and run it to a floor drain.

D

. Assemble the Plastic Tube to the Barrel Valve and then

onto the Inlet Tube. (See illustration 1).

E

. Have a plumber tap the Saddle Valve Assembly into

the copper water line.

INSTALLATION / OPERATION INSTRUCTIONS

Riv-nut locations

Dipwell Backplate installation

Dipwell bowl installation

10" Deep Drawn
"Dipwell"

Backplate

1/4"-20nc x 5/8"
S.S.T. Pan Head
Machine Screw

Inlet
Tube

Inlet
Tube
Clip

Leather Gasket

Overflow
Tube

Barrel Valve

Male Connector
Assembly

Ferrule

Saddle Valve Assembly

Riv-Nut
Locations

Riv-Nut
Locations

Illustration 1

Leather Gasket

Coupling Nut

Tail
Piece

Barrel
Valve

Ferrule

10" Deep Drawn
"Dipwell"

Overflow Tube

Inlet Tube

Inlet Tube Clip

S.S.T. Pan Head
Machine Screws

Backplate

Male Connector
Assembly

Male
Connector
Assemblies

1/4” Plastic Tubing

(leading toward water source

[saddle valve assembly])

Coupling Nut

Tail Piece
( 1” Connection
will be needed
for the drain).

1

2

3

Advertising