Warning, Adapter plugs, How to connect electricity – True Manufacturing Company TDC-47 User Manual

Page 5: Use of

Advertising
background image

............ www.truemfg.com ............

True Food Service Equipment, Inc.

3

3

SAFETY INFORMATION

The power cord of this appliance is equipped

with a grounding plug which mates

with a standard grounding wall outlet

to minimize the possibility of electric shock

hazard from this appliance.
Have the wall outlet and circuit checked by a qualified

electrician to make sure the outlet is properly grounded.
If the outlet is a standard 2-prong outlet, it is your

personal responsibility and obligation to have it replaced with

the properly grounded wall outlet.
The freezer should always be plugged into it’s own

individual electrical circuit, which has a voltage rating

that matches the rating plate.
This provides the best performance and also prevents

overloading building wiring circuits which could cause a

fire hazard from overheated wires.
Never unplug your freezer by pulling on the power cord.

Always grip plug firmly and pull straight out from the

outlet.
Repair or replace immediately all power cords that have

become frayed or otherwise damaged. Do not use a cord

that shows cracks or abrasion damage along its length or

at either end.
When removing the freezer away from the wall, be

careful not to roll over or damage the power cord.

HOW TO CONNECT ELECTRICITY

Do not, under any circumstances, cut or remove the ground prong from the power cord.

For personal safety, this appliance must be properly grounded.

WARNING!

USE OF

ADAPTER PLUGS

NEVER USE AN ADAPTER PLUG! TRUE will not warranty any freezer that has been connected to an adapter plug.

North America Use Only!

NEMA plugs

TRUE uses these types of plugs.

If you do not have the right outlet

have a certified electrician install

the correct power source.

115/60/1

NEMA-5-20R

115/208-230/1

NEMA-14-20R

115/60/1

NEMA-5-15R

208-230/60/1

NEMA-6-15R

NEMA plug confi gurations

T-Series and GDM Freezers

Spec Series same as T-Series

Back Bar
Milk Coolers
TSSU
TPP
TWT
TUC
TRCB
T-Series and GDM Refrigerators
Double Duty, Single Duty, Curved Glass

Horizontal Freezers

GDIM

TAC (Air Curtain)

The incoming power source to the cabinet including any

adapters used must have the adequate power available

and must be properly grounded. Only adapters listed

with UL should be used.