Table PD-1 — Gross Cooling Capacities (MBH)

3 Ton Single/Three Phase

WSC036A1, A3, A4, AW

Ambient Temperature (F)

85

95

105

115

Enter.
Dry

Entering Wet Bulb (F)

CFM

Bulb

61

67

73

61

67

73

61

67

73

61

67

73

Airflow

(F)

MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC

75

34.7 28.9 39.7 22.6 42.4 15.3 31.6 27.3

37.1 21.4 41.0 14.4 28.5 25.6 33.8 19.8 39.0 13.3 25.3 24.0 30.2 18.2 36.1 12.0

80

35.4 34.8 39.8 28.1 42.9 21.0 32.5 32.5 37.2 26.8 41.3 20.0 29.9 29.9 33.9 25.2 39.1 18.9 27.4

27.4 30.4 23.6 36.2 17.6

1080

85

37.7

37.7 40.1 33.5 43.4 26.1 35.3 35.3 37.6 32.4 41.5 25.3 32.7 32.7 34.4 30.8 39.3 24.4 30.1 30.1 31.0 29.2 36.3 23.1

90

40.0 40.0 40.7 38.9 43.9 31.0 38.0 38.0 38.3 38.1 41.9 30.4 35.6 35.6 35.6 35.6 39.5 29.8 32.9 32.9 32.9 32.9 36.6 28.6

75

35.7 30.8 40.3 23.5 42.7 15.5 32.5 29.2 37.9 22.3 41.4 14.6 29.3 27.5 34.6 20.8 39.4 13.6 26.2 25.9 30.9 19.1 36.8 12.4

80

36.6 36.6 40.5 29.5 43.3 21.9 34.1 34.1 38.1 28.5 41.7 20.9 31.4 31.4 34.8 26.9 39.7 19.8 28.7 28.7 31.2 25.3 36.9 18.5

1200

85

39.3 39.3 40.9 35.4 43.9 26.9 37.0

37.0 38.5 34.6 42.0 26.3 34.4 34.4 35.4 33.2 39.8 25.7 31.7 31.7 32.0 31.6 37.0 24.6

90

41.4 41.4 41.6 41.2 44.4 32.2 39.6 39.6 39.6 39.6 42.5 31.8 37.3

37.3

37.3

37.3 40.2 31.6 34.6 34.6 34.6 34.6 37.3 30.6

75

36.6 32.7 40.7 24.5 43.0 15.8 33.4 31.0 38.5 23.3 41.7 14.9 30.2 29.4 35.3 21.8 39.8 13.8 26.9 26.9 31.5 20.1 37.2 12.7

80

38.1 38.1 41.0 30.7 43.6 22.6 35.5 35.5 38.7 30.0 42.1 21.6 32.8 32.8 35.6 28.6 40.1 20.6 30.0 30.0 31.9 26.9 37.4 19.4

1320

85

40.4 40.4 41.5 37.0 44.2 29.4 38.4 38.4 39.3 36.7 42.6 27.5 35.9 35.9 36.4 35.5 40.3 26.9 33.0 33.0 33.0 33.0 37.6 26.0

90

42.4 42.4 42.4 42.4 44.8 33.2 40.8 40.8 40.8 40.8 42.9 33.1 38.7 38.7 38.7 38.7 40.8 33.2 36.1 36.1 36.1 36.1 38.0 32.6

75

37.3 34.5 41.0 25.1 43.3 16.0 34.2 32.9 38.9 24.3 41.9 15.1 30.8 30.8 35.8 22.8 40.1 14.1 27.9

27.9 32.0 21.2 37.6 13.0

80

39.2 39.2 41.4 31.9 43.9 23.4 36.8 36.8 39.2 31.5 42.4 22.1 34.0 34.0 36.2 30.2 40.4 21.4 31.1 31.1 32.6 28.6 37.8 20.2

1440

85

41.3 41.3 42.0 38.5 44.5 28.2 39.5 39.5 40.0 38.6 42.9 28.2 37.1

37.1

37.1

37.1 40.7 28.0 34.3 34.3 34.3 34.3 38.0 27.3

90

43.1 43.1 43.1 43.1 45.1 34.1 41.7 41.7 41.7 41.7 43.3 34.3 39.7 39.7 39.7 39.7 41.3 34.7 37.3

37.3

37.3

37.3 38.6 34.4

Notes:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.
2. MBH = Total Gross Capacity
3. SHC = Sensible Heat Capacity

Table PD-2 — Gross Cooling Capacities (MBH)

4 Ton Single/Three Phase

WSC048A1, A3, A4, AW

Ambient Temperature (F)

85

95

105

115

Enter.
Dry

Entering Wet Bulb (F)

CFM

Bulb

61

67

73

61

67

73

61

67

73

61

67

73

Airflow

(F)

MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC MBH SHC

75

45.9 38.6 52.2 29.8 55.3 20.0 42.3 36.5 49.6 28.8 54.2 19.0 38.5 34.5 45.8 26.5 52.4 17.8 34.7 32.5 41.5 25.0 49.5 16.4

80

47.0 46.5 52.4 37.2 55.9 27.7 43.6 43.6 49.8 35.9 54.7 26.7 40.5 40.5 45.9 34.0 52.6 25.3 37.3

37.3 41.8 32.0 49.6 23.9

1440

85

50.1 50.1 52.8 44.4 56.6 34.0 47.4

47.4 50.2 43.4 55.0 33.4 44.3 44.3 46.6 41.6 52.9 32.8 41.1 41.1 42.5 39.6 49.8 31.3

90

52.9 52.9 53.6 51.5 57.2 40.3 50.9 50.9 51.3 51.1 55.5 40.2 48.1 48.1 48.1 48.1 53.2 39.8 45.0 45.0 45.0 45.0 50.0 38.7

75

47.2 41.1 52.9 31.1 55.7 20.3 43.5 39.1 50.6 29.8 54.7 19.3 39.7 37.0 46.9 28.0 52.9 18.2 35.8 35.0 42.6 25.9 50.3 16.9

80

48.7 48.7 53.2 38.9 56.4 28.2 45.7 45.7 50.8 38.0 55.2 27.7 42.5 42.5 47.1 36.2 53.3 26.5 39.2 39.2 42.9 34.2 50.4 25.1

1600

85

51.9 51.9 53.7 46.6 57.1 34.9 49.6 49.6 51.4 46.3 55.6 34.6 46.5 46.5 47.9 44.7 53.5 34.3 43.2 43.2 44.0 42.7 50.6 33.2

90

54.4 54.4 54.7 54.1 57.8 41.6 52.7 52.7 52.7 52.7 56.1 41.9 50.3 50.3 50.3 50.3 54.0 42.0 47.3

47.3

47.3

47.3 51.0 41.2

75

48.3 43.5 53.3 32.0 56.0 20.6 44.6 41.5 51.3 31.1 55.0 19.6 40.8 39.5 47.7 29.4 53.4 18.5 36.8 36.8 43.4 27.3 50.9 17.2

80

50.4 50.4 53.8 40.4 56.7 28.6 47.6

47.6 51.5 40.0 55.7 28.4 44.3 44.3 48.1 38.4 53.8 27.5 40.9 40.9 43.9 36.4 51.1 26.2

1760

85

53.3 53.3 54.5 48.6 57.5 35.6 51.3 51.3 52.3 48.8 56.3 36.1 48.4 48.4 49.2 47.7 54.1 35.7 45.1 45.1 45.1 45.1 51.3 35.0

90

55.5 55.5 55.5 55.5 58.2 42.8 54.1 54.1 54.1 54.1 56.7 43.4 52.0 52.0 52.0 52.0 54.7 43.9 49.2 49.2 49.2 49.2 51.8 43.6

75

49.3 45.8 53.8 32.9 56.3 20.9 45.7 43.9 51.8 32.3 55.3 20.0 41.9 41.9 48.5 30.7 53.7 18.9 38.1 38.1 44.1 28.6 51.3 17.6

80

51.7 51.7 54.3 41.7 57.0 29.1 49.1 49.1 52.2 41.7 56.0 28.9 45.9 45.9 48.9 40.5 54.1 28.2 42.4 42.4 44.8 38.5 51.6 27.2

1920

85

54.3 54.3 55.1 50.3 57.8 36.4 52.6 52.6 53.1 51.1 56.7 37.1 50.0 50.0 50.0 50.0 54.6 37.0 46.8 46.8 46.8 46.8 51.8 36.6

90

56.3 56.3 56.3 56.3 58.5 43.8 55.1 55.1 55.1 55.1 57.1 44.7 53.2 53.2 53.2 53.2 55.2 45.7 50.7 50.7 50.7 50.7 52.5 45.8

Notes:
1. All capacities shown are gross and have not considered indoor fan heat. To obtain net cooling subtract indoor fan heat.