Fan performance, Performance data (3, 4, 5 ton) – Trane PKGP-PRC003-EN User Manual

Page 20

Advertising
background image

20

PKGP-PRC003-EN

Performance
Data

(3, 4, 5 Ton)

Table PD-7 — Direct Drive Evaporator Fan Performance — 3, 4 And 5 Ton WSC036A, WSC048A, WSC060A

External Static Pressure (Inches of Water) & Motor Power (Bhp)

1

Standard Motor

Oversized Motor

2

Unit

High Speed

Low Speed

High Speed

Low Speed

Tons

Model No.

CFM

ESP

BHP

ESP

BHP

ESP

BHP

ESP

BHP

960

0.81

0.36

0.61

0.28

0.96

0.39

0.89

0.35

1020

0.77

0.37

0.57

0.28

0.94

0.41

0.86

0.47

1080

0.73

0.38

0.50

0.29

0.91

0.43

0.82

0.39

1140

0.69

0.39

0.42

0.29

0.88

0.44

0.77

0.40

3

WSC036A

1200

0.66

0.40

0.34

0.30

0.84

0.45

0.74

0.41

Horizontal

1260

0.60

0.41

0.26

0.30

0.80

0.46

0.70

0.42

1320

0.55

0.42

0.14

0.31

0.75

0.48

0.65

0.44

1380

0.49

0.42

0.05

0.31

0.70

0.49

0.59

0.45

1440

0.44

0.43

—-

—-

0.64

0.52

0.54

0.48

1280

0.93

0.53

0.81

0.47

1.20

0.67

0.99

0.56

1360

0.87

0.54

0.75

0.47

1.15

0.68

0.94

0.58

1440

0.80

0.54

0.68

0.48

1.10

0.70

0.88

0.60

1520

0.73

0.55

0.60

0.48

1.05

0.73

0.81

0.63

4

WSC048A

1600

0.66

0.55

0.51

0.49

1.00

0.75

0.74

0.64

Horizontal

1680

0.57

0.56

0.38

0.49

0.95

0.78

0.65

0.66

1760

0.47

0.56

0.23

0.50

0.90

0.82

0.50

0.68

1840

0.37

0.57

0.13

0.50

0.83

0.83

0.35

0.70

1920

0.27

0.57

—-

—-

0.75

0.85

—-

0.73

1600

0.90

0.78

0.82

0.64

1.20

0.90

1.05

0.85

1700

0.85

0.82

0.68

0.65

1.15

0.94

0.95

0.89

1800

0.80

0.85

0.56

0.65

1.05

0.98

0.85

0.91

1900

0.70

0.88

0.46

0.65

0.98

1.02

0.75

0.94

5

WSC060A

2000

0.60

0.90

0.30

0.66

0.90

1.05

0.65

0.95

Horizontal

2100

0.50

0.93

0.14

0.66

0.80

1.10

0.50

0.96

2200

0.40

0.95

0.05

0.67

0.70

1.12

0.35

0.96

2300

0.30

0.97

—-

—-

0.60

1.17

0.15

0.97

2400

0.20

1.00

—-

—-

0.48

1.20

—-

—-

960

0.86

0.36

0.61

0.28

1.01

0.39

0.89

0.35

1020

0.82

0.37

0.62

0.28

0.99

0.41

0.91

0.47

1080

0.78

0.38

0.55

0.29

0.96

0.43

0.87

0.39

1140

0.74

0.39

0.47

0.29

0.93

0.44

0.82

0.40

3

WSC036A

1200

0.71

0.40

0.39

0.30

0.89

0.45

0.79

0.41

Downflow

1260

0.65

0.41

0.31

0.30

0.85

0.46

0.75

0.42

1320

0.60

0.42

0.19

0.31

0.80

0.48

0.70

0.44

1380

0.54

0.42

0.10

0.31

0.75

0.49

0.64

0.45

1440

0.49

0.43

—-

—-

0.69

0.52

0.59

0.48

1280

0.98

0.53

0.86

0.47

1.25

0.67

1.04

0.56

1360

0.92

0.54

0.80

0.47

1.20

0.68

0.99

0.58

1440

0.85

0.54

0.73

0.48

1.15

0.70

0.93

0.60

1520

0.78

0.55

0.65

0.48

1.10

0.73

0.86

0.63

4

WSC048A

1600

0.71

0.55

0.56

0.49

1.05

0.75

0.79

0.64

Downflow

1680

0.62

0.56

0.43

0.49

1.00

0.78

0.70

0.66

1760

0.52

0.56

0.28

0.50

0.95

0.82

0.55

0.68

1840

0.42

0.57

0.18

0.50

0.88

0.83

0.40

0.70

1920

0.32

0.57

—-

—-

0.80

0.85

—-

—-

1600

0.95

0.78

0.87

0.64

1.25

0.90

1.10

0.85

1700

0.90

0.82

0.73

0.65

1.20

0.94

1.00

0.89

1800

0.85

0.85

0.61

0.65

1.10

0.98

0.90

0.91

1900

0.75

0.88

0.51

0.65

1.03

1.02

0.80

0.94

5

WSC060A

2000

0.65

0.90

0.35

0.66

0.95

1.05

0.70

0.95

Downflow

2100

0.55

0.93

0.19

0.66

0.85

1.10

0.55

0.96

2200

0.45

0.95

0.10

0.67

0.75

1.12

0.40

0.96

2300

0.35

0.97

—-

—-

0.65

1.17

0.20

0.97

2400

0.25

1.00

—-

—-

0.53

1.20

—-

—-

Fan motor heat (MBh) = 4.39 x Fan Bhp
Factory supplied motors, in commercial equipment, are definite purpose motors, specifically designed and tested to operate reliably and continuously at all
cataloged conditions. Using the full horsepower range of our fan motors as shown in our tabular data will not result in nuisance tripping or premature motor
failure. Our product’s warranty will not be affected.
Notes:
1. Data includes pressure drop due to wet coil and filters.
2. 5 ton oversized motor performance is with 12 x 11 FC blower wheel.

Advertising