E6 level and blink codes, E6 l – True Fitness Z7 Series User Manual

Page 47

Advertising
background image

Z 7 Tr e a d m i l l O w n e r ' s G u i d e

63

C

AR
E

AND

M

AIN
TENANC

E

The failure code displayed will be “E-5 Sensor” when receiving the E5 Sen-

sor error, enter diagnostic mode and check the error log. Below is a list of

status display codes. When the drive is faulted, the Status LED blinks out

the default code. The code will blink the proper number of times, pause

with the LED off, and then repeat the code.

STATUS CODE

DESCRIPTION

IMPLICATION

No Blink (Steady On)

No Faults

Running

Fast (Steady Blink)

No Faults

Ready

LED Off

AC Line Power

Insufficient

No or Low Voltage

1 Blink (E601)

100% Command

Runaway Command

2 Blink (E602)

Sensor Feedback Error

Sensor Error

3 Blink (E603)

Voltage Trip Error

Motor Issue

4 Blink (E604)

Output Over Current

High Motor Current

5 Blink (E605)

Control Supply Under

Voltage

Inadequate Power Line

6 Blink (E606)

Drive Over Temperature MCB Over Tempera-

ture

7 Blink (E607)

AC Over Voltage

Line Voltage Too High

8 Blink (E608)

Output Short Circuit

Short Circuit to Motor