Diagnostics (cont.) – True Fitness Z7 Series User Manual

Page 49

Advertising
background image

Z 7 Tr e a d m i l l O w n e r ' s G u i d e

65

C

AR
E

AND

M

AIN
TENANC

E

6. Press (up arrow) to display User Not Present function.

The following messages will display:

CURRENT SHUT

No. of seconds until treadmill shuts off

with no user on treadbelt

7. Press (up arrow) repeatedly to display list of errors.

The service/error codes will be listed. See Error and Service Codes on

the previous page.

8. Press (up arrow) to display program time.

The following messages will display:

MAXTIME

No. of minutes allowed in programmed

workouts

9. Press (up arrow) repeatedly to display the error log.

The Error Log lists the five most recent Error Codes and the distance at

which each Error Code occurred.

The following messages will display:

ERROR CODE

Distance at which error code occurred

NOTE: If there are no errors in the error log, the following message will

be displayed:

LOG EMPTY

10. Remove SAFETY KEY to exit Diagnostics.

Diagnostics (cont.)

C

ARE

AND

M

AINTENANCE

Advertising