Technical information cont – Verona WALL HUNG GAS BOILER User Manual

Page 10

Advertising
background image




2.Technical Information Cont.

ENERGY CAPACITY

Nominal heat input

(0/2000ft)

MBH 122.8

Nominal heat input

(2000/4500ft)

MBH 116.7

Minimum heat input

MBH

49.5

Maximum useful output

(0/2000ft)

MBH 100.7

Maximum useful output

(2000/4500ft)

MBH 95.9

Minimum useful output

MBH

37.0

GAS SUPPLY PRESSURE

Gas

Normal

Min

Max

Natural inwc 7.0 3.5 10.5
Propane

inwc

11.0 8.0 12.0

GAS PRESSURE AT BURNER

Gas Min

Max

Ignition

Natural inwc 0.8 5.3 2.4
Propane inwc 1.4

9.0

5.2

FLUE DESIGN

Minimum Venturi pressure inwc

0.64

Flue pipe diameter

Coaxial in

2.25/4
3.25/5

Twin split pipes

in

3.25/3.25

Nominal heat flow rate

(0/2000ft)

MBH 122.8

Nominal heat flow rate

(2000/4500ft)

MBH 116.7

Min Exhaust temperature

°F

262

Max Exhaust temperature

°F

324


INJECTORS No. Size

Natural 14

130

Propane 14

89

GAS FLOW RATE

Gas Min

Max

Natural ft³/h 48.7 121.1

Propane

lb/h 2.23 5.55

ELECTRICAL

Voltage V

120

Frequency Hz

60

Current A

<

1.6

Power consumption

W

176

FLUE GAS FIGURES

Gas Min

Max

CO

2

2.5% 7.2%

O

2

16.5% 8.1%






















RIVA HEAT ONLY MANUAL - REV A