15. Commissioning Cont.

15.9 Checking the flue system and combustion:

• The flue system should be visually checked for soundness. Check all clamps, gaskets

and fixings are secure and tight.

• Ensure that the flue terminal is sited correctly in accordance with the flue fitting

instructions.

To check the exhaust gas:
• Remove the plugs

indicated (Fig. 15.11).

• Insert the analyzer

probe in the exhaust
gas sampling point or
in the air intake
sampling point.

• Reference tables are

given in the Sections
2 on page 10 of this
manual for proper
CO2 levels.

Air-Flue exhaust

sampling points

Figure 15.11

15.10 Instructing the user:

• Hand over the User manual, this Installation,Operation and Service manual to the end

user and explain how to use the unit in Central Heating mode.

• Take the User step by step through the lighting instructions.
• Show the User how to switch off the appliance quickly and indicate the position of the

electric service switch and the boiler on/off switch.

• Explain the proper use and adjustment of all system controls; this will ensure the

greatest possible safety and fuel economy.

• Explain the function and use of the function switch.
• Explain how to turn off the appliance for both short and long periods and advise on the

precautions necessary to prevent damage should the appliance be inoperative when
freezing conditions may occur.

• Fill in the details required on the Boiler Guarantee Certificate and hand to the User

advising them to return the correct section for boiler Guarantee registration. Finally,
advise the User that, for continued safe and efficient operation, the appliance must be
serviced by a competent person at least once a year.

Useful output

KW

Kcal/h

10.8

9288

12.0

10320

14.0

12040

17.0

14620

20.0

17200

23.0

19780

26.0

22360

29.5

25370

Pa

inwc

220

0.88

250

1.00

330

1.32

470

1.89

640

2.57

830

3.33

1050

4.22

1330

5.34

Natural

m³/h 48.7 53.0 60.7 72.4 84.0 96.0 107.7 121.1

Pa

inwc

360

1.45

420

1.69

560

2.25

800

3.21

1080

4.34

1400

5.62

1760

7.06

2230

8.95

Propane

lb/h 2.2 2.4 2.8 3.3 3.9 4.4 4.9 5.5

Tab 15.1




RIVA HEAT ONLY MANUAL – REV A

35

Advertising