Volkswagen 01M User Manual

Page 58

Advertising
background image

AUTO TRANS DIAGNOSIS - 01M

Article Text (p. 58)

1996 Volkswagen Golf

For Volkswagen Technical Site

Copyright © 1998 Mitchell Repair Information Company, LLC

Thursday, August 19, 1999 11:28PM

Valve Body Bolts .................................. 44 (5)
Valve Body Conductor Strip Bolt .................. 89 (10)
ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД

TRANSMISSION SPECIFICATIONS

TRANSMISSION SPECIFICATIONS
ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД
Application In. (mm)

Clutch Clearance
Apply Clutches ..................................... (1)
Brake Clutches
2nd-4th ..................... (2) .060-.068 (1.50-1.74)
Reverse ........................... .047-.071 (1.2-1.8)
Gear & Shaft End Play
Planetary Carrier .................. .009-.014 (.23-.37)
1st-3rd To Reverse Apply Clutch ... .019-.047 (.50-1.20)
Turbine Shaft ..................... .019-.047 (.50-1.20)

(1) - Assembled clutch clearance is not available.
(2) - See TRANSMISSION under TRANSAXLE REASSEMBLY.
ДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДДД

TECHNICAL SERVICE BULLETINS

SHIFTING ERRATIC, HARSH OR DELAYED

1993-On Cabrio, Golf, GTI, Jetta & Passat (Group 01, TSB No.
97-01, 1-8-97)
Transaxle may shift erratic, harsh or hold shifts too long
(delayed upshifts) with no trouble codes stored in memory. This
condition is normally caused by improper throttle angle setting. If
shifting quality is a concern, perform THROTTLE ANGLE SETTING
procedure.

NOTE: On a newly installed TCM, basic settings must be set prior
to performing the following procedure. Basic settings can be
set with Scan Tool (VAG 1551) using Function "04", Display
"OOO".

Throttle Angle Setting
1) Connect scan tool. Turn ignition on. Press "1" to select
RAPID DATA TRANSFER. Enter address word 02 "TRANSMISSION ELECTRONICS"
and advance until "SELECT FUNCTION XX" appears in scan tool display.
2) Press buttons "0", then "8" to select function 08 "READ
MEASURING VALUE BLOCK". Press "Q" button to confirm input. Press "Q"
button once more, then enter group No. 001. Press "Q" button to
confirm input.
3) Print screen. While observing scan tool display, slowly
press accelerator pedal until display reads 25 percent. DO NOT release

Advertising