Terminator character, Single cycle upload, Baud rate – Worth Data 5000 User Manual

Page 39

Advertising
background image

38

Terminator Character

I/O SETTINGS
HOST -------------

HID KEYBOARD

1

TERMINATOR CHARACTER -

CR

2

SINGLE CYCLE UPLOAD

OFF

3

BAUD RATE ----------------------

9600

4

PARITY ---------------------------

NONE

5

DATA BITS -----------------------

8

BITS

6

USB ENUMERATION DELAY:

0

7

USB HID SPEED ----------------

FAST

8

USB HID ALT OUTPUT ------

OFF

9

DONE/EXIT ------------------------------------

0

CHANGE SETTING #: _

o The Terminator Character is the character sent at the end of each data entry in NON PORTABLE mode and at the end of

each field when uploading after data collection (Portable use). Your application will determine what Terminator Character
(if any) you use. Options for Terminator Character Are: CR, TAB, CR/LF, NONE. Pressing the Number 2 on the TriCoder
keypad will cycle through those options. In HID Keyboard, CR is the default. For Serial Interface, CR/LF is the default.


Single Cycle Upload

I/O SETTINGS
HOST ----------------

HID KEYBOARD

1

TERMINATOR CHARACTER -

CR

2

SINGLE CYCLE UPLOAD

OFF

3

BAUD RATE ----------------------

9600

4

PARITY ---------------------------

NONE

5

DATA BITS -----------------------

8

BITS

6

USB ENUMERATION DELAY:

0

7

USB HID SPEED ----------------

FAST

8

USB HID ALT OUTPUT ------

OFF

9

DONE/EXIT ------------------------------------

0


CHANGE SETTING #: _

o Single Cycle Upload allows the TriCoder to upload one field at a time to the host, controlled by the pressing of any key

(except

) on the TriCoder each time the operator wants to transmit a field. Single Cycle Upload is set to OFF by

default, but when set to ON it can be used to test complex upload prefix and suffix sequences. This is typically used when a
TriCoder is used in HID KEYBOARD mode and you are uploading directly into an application. Single Cycle Upload
allows you to test key sequences and delays before you collect a lot of data and try an upload. Pressing

terminates the

upload session.

Baud Rate

Set the Baud Rate to match your serial port settings on the computer you will be uploading to.

I/O SETTINGS

HOST -----------------------------

SERIAL

1

TERMINATOR CHARACTER -

CR

2

SINGLE CYCLE UPLOAD

OFF

3

BAUD RATE ----------------------

9600

4

PARITY ---------------------------

NONE

5

DATA BITS -----------------------

8

BITS

6

PROTOCOL -----------------------

NONE

7

DONE/EXIT ------------------------------------

0


CHANGE SETTING #: _

o To change the Baud Rate you can cycle through the options by pressing the 4 key on the TriCoder keypad. Choices are:

2400, 4800, 9600, 19200, 38400, 57600, or 115200