Installation – Wayne-Dalton Z-WAVE WDTC-20 User Manual

Page 16

Advertising
background image

16

Step 7: Configuration

STEp B: Connect your wires to the corresponding terminals

on the thermostat base. Wrap wire around terminal screw

and tighten securely using a Phillips or slotted screwdriver.
noTE:

Connect O wire to the O terminal OR B wire to

the B terminal. If you have both O and B, connect O

wire to the O terminal. Do not connect B to B terminal.

See page 10 and call or e-mail customer support.

STEp a: Verify your labeled wires match the ones shown in the

box to the left.

noTE:

Do not allow the wires to contact another terminal,

touch each other or touch other parts of the thermostat.

C

RH

B

or

O

4 Wire Heat pump without auxiliary Heat + C Wiring and Jumper Configuration

Step D: Go to Page 18 to continue your installation.

G

Your Labeled Wires

SEE noTE

STEp C: On the Control Unit PCB, install jumpers as shown. See the

jumper reference guide on page 11 for jumper number designations.

Black indicates position of jumper, otherwise remove or do not place

jumper. Be certain jumpers are fully seated and in the correct position.
noTE:

For Gas Auxiliary Heat do not install or remove jumper

on jumper JP2, for Electric Auxiliary Heat set jumper JP2 in

position B.

STEp B: Connect your wires to the corresponding terminals

on the thermostat base. Wrap wire around terminal screw and

tighten securely using a Phillips or slotted screwdriver.
noTE:

Connect O wire to the O terminal OR B wire to the

B terminal. If you have both O and B, connect O wire to

the O terminal. Do not connect B to B terminal. See page

10 and call or e-mail customer support.

STEp a: Verify your labeled wire match the ones shown in the

box to the left.

noTE:

Do not allow the wires to contact another terminal,

touch each other or touch other parts of the thermostat.

C

RH

B

or

O

G

Y

Y

W2

STEp C: On the Control Unit PCB, install jumpers as shown. See the

jumper reference guide on page 11 for jumper number designations.

Black indicates position of jumper, otherwise remove or do not

place jumper. Be certain jumpers are fully seated and in the correct

position.

5 Wire Heat pump with auxiliary Heat + C Wiring and Jumper Configuration

Your Labeled Wires

JP5 JP3 JP4

JP2

JP1

JP5 JP3 JP4

JP2

JP1

O W2

C B

G A

RH RC

W Y

C

RH

G

Y

O

B

SEE noTE

Installation

Step D: Go to Page 18 to continue your installation.

OR

A

B

O W2

C B

G A

RH RC

W Y

C

RH G

Y

O

B

SEE noTE

W2

Advertising