retrofit or replacement Installations:
Mount the new thermostat in the same location

as the old one.

new Installations:
Follow the guidelines below and refer to the

diagram:

Locate the thermostat on an inside wall,

about 5 ft. above the floor, and in a room that is

used often.

Do not install it where there are unusual

heating conditions, such as in direct sunlight,

near a lamp, radio, television, radiator register,

or fireplace, near hot water pipes in a wall, near

a stove on the other side of a wall.

Do not locate in unusual cooling conditions

such as on a wall separating an unheated room,

or in a draft from a stairwell, door or window.

Do not locate in a damp area. This can lead

to corrosion that will shorten the life of the

thermostat.

Do not locate where air circulation is poor,

such as in a corner or an alcove, or behind an

open door.

Do not install the thermostat unit until all

construction work and painting has been

completed.

This thermostat does not require leveling for

proper operation.

Your thermostat is a precise instrument,

handle it with care.

• Turn off electricity to the heating and

air conditioning units before installing

or servicing the thermostat or any part

of the system.

• Do not turn electricity on again until

work is completed.

• Do not short (jumper) across electric

terminals at control on furnace or air

conditioner to test the system. This will

damage the thermostat and void your

warranty.

• All wiring must conform to local

codes and ordinances.

• This thermostat is designed for use

with 24 volt AC systems. The thermostat

should be limited to a maximum of 1.0

amps, higher amperage may cause

damage to the thermostat.

Step 1: Thermostat Location

Installation

CaUTIon:

Continued Next Page