Installation – Wayne-Dalton Z-WAVE WDTC-20 User Manual

Page 9

Advertising
background image

9

General wiring guidelines for safe and

secure wire connections:

Ends of wires should be stripped 3/8 inch

as shown.

Take care not to damage or lose labels for

each wire during handling.

Locate and dress wires to come in from

behind the thermostat and turn up into the

terminal area.

Push excess wiring back into the wall

opening. Do not allow wiring between

thermostat mounting base and wall.

Connect labeled wires only to a terminal

with a corresponding letter.

note:

Be careful, do not allow bare

wires to touch, or short, each other.

Use the wiring diagrams on page 12 and

cross reference chart on page 13 for your

exact application as your guide.

Fan wires out as illustrated in the wiring

diagrams with the Z-Wave

®

enabled

thermostat mounting base positioned below

the wall opening.

Insert the wire in the terminal and tighten

the screw securely.

Set the control unit configuration jumpers

per the Wiring and Jumper configurations

found on pages 14-17, choosing the one that

matches your wiring needs. A needle-nose

pliers may be required to remove the jumper

to modify its position.

Step 4: Wiring Information

Installation

Terminal Block

in Mounting

Base

Wiring Strip

length is 3/8

inch

note:

Numbered Jumper Locations JP1 -

JP5 are referenced in illustration above

and in the wiring diagrams on the following

pages.

Continued Next Page

JP1 JP2

JP5

JP3

JP4