Wayne-Dalton Z-WAVE WDTC-20 User Manual

Page 20

Advertising
background image

Celsius/Fahrenheit readout

20

adv

anced Installation Information

Temperature offset

Your Wayne-Dalton Z-Wave

®

enabled

Thermostat is very accurate and

comes from the factory calibrated

to +/- 1º of actual temperature.

Temperature offset can be used

to force the thermostat to match

another thermometer in your home

to a maximum of +/- 6º.

1. Remove Thermostat Control Unit

from the thermostat base.

2. Slide the calibration switch to the

ON position.

3. Press either the + or - button on the

front of the Control Unit until the desired

temperature offset factor is reached.

4. Slide the Calibration switch to the

OFF position.

noTE:

If using this feature,

Temperature Offset must

be adjusted each time the

thermostat is RESET or batteries

are removed.

Example: Display shows +2 degree Offset factor

JP1

ON

OFF

JP1

OR

A

B

Modify your display to read

degrees C or degrees F:

To display degrees Celsius:
1. Install jumper on jumper JP1
position A shown in diagram to the
right.
2. Press and release the RESET
button (using a paper clip or pencil
point) on the front of the control
unit to activate your setting.

To display degrees Fahrenheit:
1. Do not install jumper or remove
jumper on jumper JP1 as shown
on position B in the diagram to the
right.
2. Press and release the RESET
button on the front of the control
unit to activate your setting.

SAVE

ENERGY

NORMAL

RESET

2

3

Calibrate

switch

OFF

ON

2

4

CALIB

Advertising