Installation

Step 7: Configuration

STEp B: Connect your wires to the corresponding

terminals on the thermostat base. Wrap wire around

terminal screw and tighten securely using a Phillips or

slotted screwdriver.

STEp a: Verify your labeled wires match the ones shown in the

box to the left.

noTE:

Do not allow the wires to contact another terminal,

touch each other or touch other parts of the thermostat.

C

RH

W

2 Stage Heat and 1 Stage Cool + C Wiring and Jumper Configuration

Step D: Go to Page 18 to continue your installation.

G

Your Labeled Wires

STEp a: Verify your labeled wires match the ones shown in the

box to the left.

noTE:

Do not allow the wires to contact another terminal,

touch each other or touch other parts of the thermostat.

C

A

W

3 Wire Zoned Hot Water Heat + C Wiring and Jumper Configuration

Important operation note:

For 3 wire hot water system applications, the thermostat must

be used in Heat and Heat Save Energy modes ONLY, in order to maintain power to the solenoid

valves in the OFF position.

Step D: Go to Page 18 to continue your installation.

Your Labeled Wires

Y

RH

STEp C: On the Control Unit PCB, install jumpers as shown. See the

jumper reference guide on page 18 for jumper number designations.

Black indicates position of jumper, otherwise remove or do not

place jumper. Be certain jumpers are fully seated and in the correct

position.

noTE:

For Electric Heat set jumper JP5 in position A, for Gas

or Oil Heat set jumper JP5 in position B.

SEE noTE

A

OR

B

G

O W2

C B

G A

RH RC

W Y

W2 W

RH

C

Y

W2

O W2

C B

G A

RH RC

W Y

C W

RH

A

STEp B: Connect your wires to the corresponding terminals on the

thermostat base. Wrap wire around terminal screw and tighten

securely using a Phillips or slotted screwdriver.
noTE:

For a Motor driven Valve connect “W” wire to “W”

terminal and connect the 3rd wire to the “A” terminal. For

a Solenoid valve connect “W” wire to “A” terminal, and

connect the 3rd wire to “W” terminal.

(all 3 wires must be connected)

SEE noTE

STEp C: On the Control Unit PCB, install jumpers as shown. See the

jumper reference guide on page 11 for jumper number designations.

Black indicates position of jumper, otherwise remove or do not place

jumper. Be certain jumpers are fully seated and in the correct position.

JP5 JP3 JP4

JP2

JP1

JP5 JP3 JP4

JP2

JP1