LX and LT Pool Heaters

Page 9

2.

Remove the factory installed jumper wire and tag

from the terminal strip (see Figure 10).

3.

Connect the low voltage wires from the time clock

auxiliary switch to the two terminals. Use American

Wire Gage (AWG) No. 14 gauge stranded copper

wire with a temperature rating of 221°F (105°C) or

greater (see Figure 11).

If your time clock simply interrupts the high

voltage power supply or has a high voltage output, do not

connect the power supply of the heater to the output

side of the clock. Doing so will prevent the blower from

purging the residual heat from the heater when the heater

turns off. This situation will damage the heater. The

blower must be allowed to run for 45 seconds after the

heater shuts off.

2H-4. Remote Operation

(Model LX Only)

The Laars LX pool/spa heater controls can be wired

for remote operation. All Waterpik Technologies/Jandy RS

Control Systems will permit the heater to be operated by

remote control. If you are setting up a new pool or spa

system, call your local distributor or the Waterpik

Technologies/Jandy Customer Service Department for

information on the correct RS Control System to meet your

needs.

To connect a Laars LX heater to an existing RS

Control System, first determine the revision level the

programmed chip in the RS Control System's Power

Center Board. To check the revision level of the chip,

press and hold the reset button on the side of the indoor

control panel for 10 seconds then release it. A number will

appear on the display for approximately 5 seconds. This

first number can be ignored. After the first number

disappears, a second number will appear in the display

window. It will consist of 4 digits followed by a revision

level ("#### REV _"). If the revision level displayed here

is at "H" or higher it will accommodate a Laars LX heater

without any modification. If the chip is at a revision "G" or

lower the chip will have to be replaced with a newer

version. An alternate method for determining the revision

level of the programmed chip in your RS control, is

described in steps 1-4 below. An updated chip can

obtained through Waterpik Technologies/Jandy by

ordering the PPD Kit. Instructions for changing the chip

are in the kit.

Do not connect more than two wires to any of the

terminals in the RS Control System when connecting

peripheral devices. If connecting the LX heater to the RS

Control System creates this situation, then a Multiplexing

PCB kit must be used. Call your distributor or Waterpik

Technologies to order the kit.

To connect the Laars LX to your RS control System,

follow the steps listed below (See fig. 12).

1. Turn off the power to the heater and the RS

Control.

2. Open the RS Power Center Enclosure and

remove the front dead panel.

NOTE: Only a revision “H” or higher program chip in

the RS system will support the LX Heater

Interface.

Figure 12. Wiring a Laars LX to a Jandy RS Remote

U1

J4

W0

1 RED
2 BLK
3 YEL
4 GRN

JVA Board

1

8

1

5 1

Bezel

RS CONTROL

SYSTEM

LX CONTROL

INDOOR CONTROL

22 GAGE, 4

CONDUCTOR

WIRE

Figure 10. Remove Jumper from Terminal Block

LEFT SIDE OF

RACEWAY

TERMINAL BLOCK

REMOVE JUMPER

WIRE

Figure 11. Typical Time Clock Wiring.