Waterpik Technologies pool/spa heater User Manual

Page 22

Advertising
background image

Page 20

Below the Backlight indicator is an RS service

indicator, which displays ‘RS Online’ when the heater is

connected to an RS unit.

Directly below the RS Service indicator on the

bottom right hand portion of the LCD screen is the

Fahrenheit/Celsius temperature unit indicator.

The Model LT does not offer these features.

3B-2. Turning the Heater On or Off

When power is supplied to the Model LX heater, the

control goes into a diagnostic mode for approximately 15

seconds before the heater can be turned to the Pool or Spa

mode. During this time the display will show "RS Online".

If there is an RS control connected to the heater, it will

sense the RS unit and remain online. If the control is not

connected to an RS unit the "RS Online" indication on the

display will disappear after the initial 15 seconds. When

the display shows "RS ONLINE" all functionality of the

control at the heater is disabled. The heater functions can

be controlled only at the RS unit. However, sensor data is

displayed at both the heater and the RS unit.

To temporarily use the heater controls when online

with an RS control unit, use a thin object to depress the

button marked "RS SERVICE". The "RS ONLINE"

indicator will disappear from the heater display. All

functionality has now been returned to the control at the

heater. In this mode the RS unit has been disabled. To

return the functionality to the RS unit, push the button

again.

When power is first supplied to the Model LT

heater it also runs through a circuit board diagnosis to

make sure that the control is working correctly. Indicator

lights will flash during the 10 second diagnostic sequence.

After the initial diagnostic sequence on the Model

LX, the heater can be turned to Pool or Spa mode by

pressing and releasing the top (mode) button to the right of

the LCD screen so that the selector arrow is aligned with

either the Pool or Spa setting as seen on the LCD screen.

The Model LT heater does not offer the remote

control indicator function. To turn the heater on, press and

release the button located between the "POOL" and "SPA"

indicator lights. Repeat pressing the button to achieve the

desired mode of operation, shown by the indicator lights.

When neither light is on, the heater is "OFF"

It is now necessary to set the thermostat to the

desired pool or spa setting.

3B-3. Setting Pool and Spa Temps,

Changing from Fahrenheit to

Celsius

The Model LX heater displays temperature in

Fahrenheit units when powered-up. To switch to Celsius,

press the ‘F°/C°’ button. Once the desired temperature

units are selected, the thermostat can be set. The left-most

button below the LCD screen, labelled "Select", will select

either the Pool or the Spa thermostat when depressed.

Either "Pool" or "Spa" will be displayed in the bottom left

corner of the LCD screen. The ‘up’ and ‘down’ buttons

will increase or decrease the thermostat setting.

The Model LT heater control is less quantitative and

not automatic. The pool or spa water temperature will need

to be monitored manually as the control is adjusted.

Temperature adjustments are made by turning the knob

assosiated with the mode labeled below it. Turning the

knob clockwise will increase the temperature setting.

Turning it counterclockwise will decrease the setting.

Once the desired setting is acheived, set the temperature

lock by loosening the screw located at the bottom of the

knob and rotating the dial stop counterclockwise until it

contacts the knob. Tighten the screw to lock the stop in

place.

When the thermostat setting exceeds the temperature

of the pool or spa, the heater will fire. The heater will fire

continuously until the pool or spa water is heated to the

selected thermostat temperature. The control will not allow

the heater to fire again for five minutes even if there is a

call for heat, unless the thermostat setting is increased. In

this case, the heater will fire within two minutes. This is to

prevent short-cycling, and thereby increase the life of the

heater.

When the Model LX heater is firing, "Heating" will

be displayed underneath the LAARS LX logo. Note that in

both the "POOL" and "SPA" thermostat settings, the

temperature cannot be raised above 104°F (40°C).

Note that if power is momentarily lost, the

thermostat settings will remain the same.

Also note that the heater should not be used to

maintain water temperatures at or below 70°F (21°C). This

will damage the heater.

3B-4. Error Status

If the heater is powered, in either pool or spa mode,

and there is a call for heat (i.e. the thermostat setting is

higher than the water temperature) the heater will fire.

The blower will come on for approximately 30 seconds,

FIGURE 22. GAS VALVE