Lx and lt pool heaters, 3g. seasonal care 3g-1. spring and fall operation, 3g-2. winterizing – Waterpik Technologies pool/spa heater User Manual

Page 27: 3h. periodic inspection, 3h-1. owner inspection

Advertising
background image

LX and LT Pool Heaters

Page 25

5.

Disconnect the copper tubing from the pressure

switch fitting (see Figure 24).

6.

Cover the vent grille so that snow will not

accumulate in the combustion blower, where it may

freeze.
To reactivate the heater in the spring, have a

qualified professional technician reassemble the heater as

follows:
1.

Attach the pressure switch fitting to the copper tubing

(see Figure 24).

2.

Tighten the drain plugs in the headers.

3.

Uncover the vent grille.

4.

Turn on the main supply gas cock outside the heater

jacket.

5.

Turn on the heater according to the lighting and

shutdown instructions on the back of the heater door.

6.

During the winter shut down the heater by following

the lighting and shutdown instructions in Section 3A.

When on vacation for longer than a week, make sure

the heater is shut off at the temperature control panel.

7.

Where possible, shelter the pool from prevailing

winds with well-trimmed hedges or other

landscaping, cabanas, or fencing.

8.

Always use a pool cover when practical. Besides

providing a valuable safety feature, a pool cover will

reduce heat loss, conserve chemicals, and reduce the

load on filter systems.

3G. Seasonal Care

3G-1. Spring and Fall Operation

During periods when the pool is only going to be

used once in a while, set the thermostat control to the

lowest temperature for both modes. This prevents the pool

from becoming "chilled," yet still requires the least amount

of time to raise the water back up to swimming

temperature.

If the heater is not going to be used for a long period

of time, shut it down completely, following the

instructions in Section 3C-2 'Shutdown', or the lighting

and shutdown instructions posted inside the heater.

3G-2. Winterizing

If you don't plan to use the pool or spa over the

winter and your area is subject to freezing temperatures,

have a qualified professional technician perform the

following steps to protect the heater:
1.

Shut off the heater's gas valve according to the

lighting and shutdown instructions.

2.

Shut off the main supply gas cock outside the heater

jacket.

3.

Completely drain the heater before the first frost. To

drain the heater, remove the drain plug from the right

side of the inlet/outlet header (see Figure 23).

4.

Return the drain plug to the manifold, but do not

tighten.

FIGURE 23. Draining the Heater

O-RING

DRAIN PLUG

FIGURE 24. WINTERIZING THE PRESSURE SWITCH

TO

WINTERIZE:

DISCONNECT

SIPHON

LOOP

RECONNECT

SIPHON

LOOP

BEFORE

STARTING

THE HEATER

SIPHON

LOOP

PRESSURE

SWITCH

3H. Periodic Inspection

Improper installation or maintenance can

cause nausea or asphyxiation from carbon

monoxide or flue gases which could result in

severe injury, property damage, or death.

3H-1. Owner Inspection

Waterpik Technologies has designed and constructed

the LX heater to provide long performance life when

installed and operated properly under normal conditions.

The following basic guidelines should be maintained:
1.

Keep the top of the heater clear of all debris, and

make sure there is no collecting of flammable

materials, leaves, paper, etc., around or beneath the

heater.

2.

Keep the pool heater area clean and free of all

combustible materials, gasoline and other liquids,

and vapors.

WARNING