Troubleshooting assistance guide, Programming (continued) – White Rodgers SuperStat Pro Programmable Thermostat User Manual

Page 40

Advertising
background image

Troubleshooting Assistance Guide

38

SuperStat Pro User Guide

Programming
(continued)

Thermostat does not follow programmed times.

• The thermostat has an intelligent algorithm (Energy Recovery Management) that

automatically starts the heating/cooling system before the scheduled start time so that
the desired temperature is reached at the scheduled start time.

• The thermostat maybe set in the Hold (override) mode. Press RUN to reset the hold

and go back to the programmed setpoint.

• Recheck program for current setting versus the program settings.
• Make sure AM and PM are correct for each period in the program.

In program mode, the time or temperature displays “--”.

Display of dashes (- -) during programming means that there are different values
programmed into the days within the selected group of days. For example, if you are
programming the weekdays (Monday – Friday) together as a group and Monday has a
different setpoint or start time, the display will show the dashes in the respective locations.
To overwrite the value so that all days are the same, simply press the

TIME/SET button

until the right element (time or setpoint) is flashing, press the UP/DOWN arrow buttons to
set the value. This will overwrite the entire group to the same value.

Advertising