Wegener Communications UNITY 4600 User Manual

Page 13

Advertising
background image

www.wegener.com

800032-01 Rev. G

7

Unity 4600 User’s Manual

Max E

b

/N

0

@ Quasi-error-free threshold

(less than one uncorrected error-event per
hour)

Per EN300 421:

QPSK R=1/2: 4.5 dB,

QPSK R=2/3: 5.0 dB,

QPSK R=3/4: 5.5 dB,

QPSK R=5/6: 6.0 dB,

QPSK R=7/8: 6.4 dB

RF Power Level Estimator

(locked to carriers or not)

Unitless metric SIGNAL corresponds to input power as follows:

above -25dBm

-25dBm

-35dBm

-45dBm

-55dBm

-65dBm

below -65dBm

no signal

Extrapolated from 90 up to 100+

90

70

50

30

10

Extrapolate from 10 down to <0

<0

Accuracy: unit to unit <±5 dBm; over frequency <±10 dBm

LNB DC POWER

(supplied on RF center conductor)

Activation

User- or network-controlled selectable: ON or OFF

Voltage

~ +18.7 VDC nominal at no loading, +18.0 VDC min. at max
loading

Current (full load)

350 mA max

Short-circuit protection

Thermal fuse, tripping at ~500 mA.

European “Universal LNB”

Software may be upgraded for “Universal Single LNB”
polarization and freq-band control per ASTRA recommendation

DVB-QPSK RECEIVER WITH 4-PORT RF SWITCH OPTION

SWITCHED RF INPUTS

Input Impedance

75

Ω unbalanced

Isolation, port-to-port

> 45 dB, 950-1450 MHz

> 40 dB, 1450-2150 MHz

Input VSWR, 75-

Ω system, selected port

< 2.6:1 (7 dB R.L. min), 950-1450 MHz

Not guaranteed, 1450-2150 MHz

Input VSWR, 75-

Ω system, unselected port < 2.0:1 (10 dB R.L min), 950-1450 MHz

Not guaranteed, 1450-2150 MHz

Characteristic

Specification

Advertising