Monitoring and control, Figure 1.5, Unity 4600 functional block diagram – Wegener Communications UNITY 4600 User Manual

Page 34

Advertising
background image

Operation

28

800032-01 Rev. G

www.wegener.com

Several user- or network-programmable objects control the Automated Recovery. In
addition to the contents of the Preset Table, these objects include the Services Recovery
Timeout, the Network Recovery Timeout, the Recovery Iteration Time, and the Local
Control Re-enable Timeout. The first two timeouts control how long the unit will wait after
loss of services or network control, respectively, before entering Automated Recovery. The
Recovery Iteration Time sets the maximum time the unit will spend attempting recovery at
each preset. The last is a special timeout for disaster recovery, such as loss of a satellite,
where units whose local control was previously disabled by the network are re-enabled so
that local users may implement more complex recovery plans.

Monitoring
and control

Most routine

Unity 4600

operations can be performed over Wegener’s COMPEL

®

Network

Control System. Control is "broadcast" to individual units through a "ghost-PID" data
component of the incoming transport stream. The

Unity 4600

is considered disconnected

from the network at any time this special stream is not being received.

In addition to the remote COMPEL network control, three methods are provided for "local"
monitoring and control of the

Unity 4600

: a web browser interface (later release), a terminal

interface (direct serial or via telnet over TCP/IP), and a front-panel interface.

Note: Local control may be limited by COMPEL command.

The remainder of this chapter details these local monitor and control interfaces.

Figure 3.1:

Unity 4600

Functional Block Diagram

Advertising