Wegener Communications UNITY 4600 User Manual

Page 55

Advertising
background image

www.wegener.com

800032-01 Rev. G

49

Unity 4600 User’s Manual

source:

1 - Not used. (In legacy IRDs, this was Fade timeout.)

2 - Services Recovery Timeout. (In legacy IRDs, this was Installation timeout.)

3 - Network Recovery Timeout. (In legacy IRDs, this was No COMPEL

®

timeout.

4 - Recovery Iteration Time. (In legacy IRDs, this was Header Seek timeout.)

5 - Local Control Re-enable Timeout. (In legacy IRDs this was Local (Control) Recovery timeout.)

time:

Time-out value in seconds or

HHHH:MM:SS

format. Minimum value is

1

, and maximum value

35999999

(9999:59:59

hms) for all others.

Command sets Automated Recovery timeout specified by source to the value specified by time.

SETUID [id]

id:

Unit ID number between

00

and

99

inclusive.

Command for assigning the unit ID number for gaining "talker" access on a shared serial bus. The factory

default setting for id is '00', which also disables terminal daisy-chain capability. If the
parameter is omitted, then this command returns the current unit ID setting. Command is
only applicable to products that feature serial "daisy-chain".

SP program

program:

Either an integer between

1

and

65,535

(representing a number) or an alphanumeric string

(representing a name), preference being on a number to resolve ambiguity.

Command changes selected

program

by Program Number (from PAT) or SDT descriptor. This command

works similarly to a PERM command.

TEMP [format] [feed #] [carrier freq] [data rate] [FEC] [Tag Site] program# time

For format, feed #, carrier freq, data rate, FEC, tag site, and program #, see

PERM

command.

time:

Length of insert in either

HH:MM:SS

format (valid range is

0:00:00

to

18:00:00

, leading zeros

OK to omit on hours) OR in number of seconds. (A one-hour

TEMP

could have a parameters:

of

1:00:00

or

3600

.)

Command which performs a volatile temporary insert for an amount of time given by time. Unit sets its

temporary Unit Settings to the values given.

Note:

No label may be applied using this terminal command.

TEMPCH value time

value:

Either the value of a Preset table entry number OR the Channel Label of an entry, priority given
to Label if any ambiguity. If an entry number, legal values range from

1

up to

N

(where

N

is

number of Preset support this product).

time:

Same as for

TEMP

.

Volatile command which sets volatile temporary Unit Settings to those retrieved from the Preset table

according to value for time given by time. Similar to TEMP command.

TEMPSENS

Command displays internal unit temperature if available.

Advertising