ZebraNet Utilities
ZebraNet Connect IP

106

14197L-001 Rev. A

ZebraNet

®

10/100 Internal Print Server for ZM400 and ZM600 User Guide

04/19/2007

ZebraNet Connect IP

ZebraNet Connect IP allows you to send jobs to print servers that use Dynamic IP addresses
(DHCP). It also notifies you of printer errors, such as

paper out

or

head open

. When

print jobs are printed through ZebraNet Connect IP, they are sent directly to 10/100 Internal PS
and are not routed through a network server, resulting in a reduction of network traffic.

Setting up a ZebraNet Connect IP

If you have printing problems while using the ZebraNet Connect IP printing port, you may
check the status of the port or change its settings through the printer Properties dialog.

• For Windows 95/98, select

Port Settings

under the Details tab.

• For Windows NT 4.0 or Windows 2000, select

Configure Port

under the Ports tab.

Windows NT 4.0/Windows 2000

If you are using the Windows NT 4.0 or Windows 2000 operating system, use the following
procedure to set up a printer port for the 10/100 Internal PS.

To set up a printer port for the 10/100 Internal PS, complete these steps:

1.

From the task bar, select

Start > Settings > Printers

.

2.

Select the Windows printer to use when printing with the 10/100 Internal PS.

3.

From the menu bar, select

File > Properties

.

4.

To add a ZebraNet Connect IP port, in the Ports tab select

Add Port

.

5.

From the list of Available Printer Ports, select ZebraNet Connect Monitor as the type of
port to add, and click

New Port

.

From the Add ZebraNet Connect Port screen, there is a list of all 10/100 Internal PS
devices available on the local subnet.

The TCP/IP monitor searches only the local subnet.

Note •

The DHCP feature of ZebraNet Connect IP can rediscover a 10/100 Internal PS on the

local subnet, even when its IP address might be changing (for example, when using DHCP for
IP address resolution). The 10/100 Internal PS is relocated by its port name as configured
through ZebraNet View (the default name is Serial Number-Port Number). This feature is
enabled on the local subnet only. A non-local 10/100 Internal PS device is not rediscovered if
the IP address changes.

Note •

If ZebraNet Connect IP monitor is not listed, verify that the ZebraNet Connect IP

software has been properly installed. To do this, you need to reinstall the software and
choose