Hardware Troubleshooting
Troubleshooting the 10/100 PS

110

14197L-001 Rev. A

ZebraNet

®

10/100 Internal Print Server for ZM400 and ZM600 User Guide

04/19/2007

Troubleshooting the 10/100 PS

Defaulting the 10/100 PS

To default the 10/100 Internal PS to factory settings using the control panel,
complete these steps:

1.

From the control panel, press

Setup/Exit

two times

.

2.

Press

Plus (+ key)

five times.

The control panel will read

DEFAULT NET.

3.

Press

Setup/Exit

to save the change.

4.

After the printer defaults all settings, the control panel will show

PRINTER READY.

10/100 Internal PS Network Status/Activity Indicator

A single LED containing a red element and a green element. By turning on and off different
combinations of these two LED elements indicate Ethernet links, activity, and speed.

ZebraNet View Utility Discovery or Configuration Problems

If you are having problems using the ZebraNet View utility to discover or configure the unit,
check the following:

• Verify there is not a router between the workstation running ZebraNet View and the

10/100 Internal PS. Because the 10/100 Internal PS does not have an IP address, TCP/IP
communication cannot be started across a router. Run ZebraNet View on the same subnet
as the 10/100 Internal PS.

• Verify that the LED on the 10/100 Internal PS is active. Consult the chart above for

details.

LED State

Description

Off

No Ethernet link detected

Green

100 Mbps link detected

Green, flickering off and on

100 Mbps link detected and Ethernet activity detected

Amber

10 Mbps link detected

Amber, flickering off and on

10 Mbps link detected and Ethernet activity detected