Yamaha RX-V2400 User Manual

Page 31

Advertising
background image

27

English

AUTO SETUP

PRE

P

ARA

T

ION

Troubleshooting for auto setup procedure

Before auto setup

During auto setup

Press –/+ to display the detailed information about the individual error. Select RETRY to try auto setup procedure again.

After auto setup

Press –/+ to display the detailed information about the individual error.

• If the warning message W-2 or W-3 appears on the OSD, no corrections are made. In such cases, correct the problem, select CHECK

in DISTANCE or LEVEL, then perform the auto setup procedure again.

• If the message W-1, W-4 or W-5 appears on the OSD, corrections are made. However, the corrections may not be correct. In such

cases, correct the problem, then perform the auto setup procedure again on the relevant setting items.

Error message

Cause

Remedy

Connect MIC!

Optimizer microphone is not connected.

• Connect the supplied optimizer microphone to the

OPTIMIZER MIC jack on the front panel.

Unplug HP!

Headphones are connected.

• Unplug the headphones.

Error message

Cause

Remedy

E-1:NO FRONT SP

Front L/R channel signal(s) is(are) not detected.

• Select the front speakers with SPEAKER A or B.
• Check the front L/R speaker connections.

E-2:NO SURR.SP

A surround channel signal is not detected.

• Check the surround speaker connections.

E-3:NO PRES. SP

A presence channel signal is not detected.

• Check the presence speaker connections.

E-4:SBR->SBL

Only right surround back channel signal is
detected.

• Connect the surround back speaker to the LEFT

SURROUND BACK SPEAKERS terminal if you
only have one surround back speaker.

E-5:NOISY

Background noise is too loud.

• Try auto setup procedure in quiet environment.
• Turn off noisy electric equipment like air conditioners

(etc.) or move it away from this unit.

E-6:CHECK SURR.

Surround back speaker(s) is(are) connected,
though surround L/R speakers are not.

• Connect surround speakers when you use (a)

surround back speaker(s).

E-7:NO MIC

The optimizer microphone was unplugged
during the auto setup procedure.

• Connect the supplied optimizer microphone to

OPTIMIZER MIC jack on the front panel.

E-8:NO SIGNAL

The optimizer microphone does not detect test
tones.

• Check the microphone setting.
• Check the speaker connections and placement.

E-9:USER CANCEL

The auto setup procedure was cancelled
because a setting which affects the auto setup
was changed during the procedure.

• Perform the auto setup procedure again.

Warning message

Cause

Remedy

W-1:OUT OF PHASE

Speaker polarity is not correct. This message
may appear depending on the speakers even
when the speakers are connected correctly.

• Check the speaker connections.

W-2:OVER 24m
(80ft)

The distance between the speaker and the
listening position is over 24 meters (80ft).

• Bring the speaker closer to the listening position.

W-3:LEVEL ERROR

The difference of volume level among speakers
is excessive. (No level correction is made.)

• Readjust the speaker installation.
• Check the speaker connections.
• Use speakers of similar quality.
• Adjust the output volume of the subwoofer.

W-4:SWFR PHASE

The phase polarity of the subwoofer is not
correct.

• We recommend that you select the opposite phase on

the subwoofer if the subwoofer has a phase switch.

W-5:VOL ERROR

The result may not be correct because the
volume was changed during the auto setup
procedure.

• Perform the auto setup procedure again. Do not

change the volume during the auto setup procedure.

00_RX-V2400U_EN.book Page 27 Friday, October 10, 2003 10:54 AM