Printer Configuration

Serial Interface

INTERFACE MENU
Serial

Note that “Serial” must be displayed on the bottom line of the display in order to access the following
features and for this interface to be active when Setup is exited.

Emulation

Emulation
Printek

Possible Values: Printek*, O’Neil, ZPL-II, Mt3, CPCL, Hex Dump

This feature sets the family of printer commands that may be used by a host application program to control the
various capabilities of the printer. The printer will only respond to commands valid for the currently selected
emulation. For more information, please refer to the MtP400 Series Programmer’s Manual.

Baud Rate

Baud Rate
57600

Possible Values: 9600, 19200, 38400, 57600*

This feature sets the baud rate for the Serial interface. The value must match the setting used on the host
system.

Data Bits

Data Bits
8

Possible Values: 7, 8*

This feature sets the number of data bits in the serial character frame. The value must match the setting used on
the host system.

Stop Bits

Stop Bits
1

Possible Values: 1*, 2

This feature sets the number of stop bits included in the serial character frame. The value must match the
setting used on the host system.