Operation, Page 88, Utility interactive operation with utility backup – Xantrex Technology 120 VAC/60 User Manual

Page 96

Advertising
background image

OPERATION

Page

88

2001 Xantrex Technology, Inc.

5916 - 195th Street N. E.
Arlington, WA 98223

Telephone: 360/435-8826

Fax: 360/435-2229

www.traceengineering.com

SW Series Inverter/Charger

Part No. 2031-5

Rev. C: February 2001

UTILITY INTERACTIVE OPERATION WITH UTILITY BACKUP

The SW Series Inverter/Charger is capable of operating both as a utility interactive and a stand-alone
inverter. This allows the system to normally sell the excess power to the utility and, once an outage has
occurred, provide power to the AC loads from the battery.

The loads that will be provided with utility backup during outages must be isolated from the non-utility
backed-up loads. This usually requires the addition of an AC load center sub panel for the output of the
inverter.

Figure 29, Utility Interactive Line-Tie System With Battery Backup Flow Diagram

TRACE SW-SERIES

INVERTER/CHARGER

120 VAC

NOTE: THE BUY AND SELL METERS

CAN BE COMBINED

INTO ONE TWO-WAY METER

IF NET BILLING IS ALLOWED.

UTILITY GRID

120/240 VAC

kWh METER WITH

DETENTS (ONE-

WAY) 120/240

VAC

“BUY” METER

AC LOADS

120/240 VAC

SOLAR
ARRAY

FUSED

DISCONNECT

PV CHARGE

CONTROLLER

WIND

GENERATOR

kWh METER WITH

DETENTS (ONE-

WAY) 120/240

VAC

“SELL” METER

BATTERY

DISCONNECT

UTILITY INTERACTIVE

LINE-TIE SYSTEM WITH

BACKUP OF CRITICAL AC

LOADS

BATTERY

STORAGE

SYSTEM

AC INPUT

TERMINAL

FUSED

DISCONNECT

FUSED

DISCONNECT

60A/120 VAC

DC BATTERY

TERMINALS

BREAKER

60A/120 VAC

SERVICE

ENTRANCE

PANEL

120/240 VAC

BREAKER

60A/120 VAC

CIRCUIT

BREAKERS

(FOR HOUSE)

FUSED

DISCONNECT

60A/120 VAC

NEMA 3R

OUTDOOR TYPE

DESIGNATES
BI-DIRECTIONAL
CURRENT PATH

OUTDOORS NEXT

TO THE UTILITY

SERVICE

ENTRANCE

NEXT TO THE

INVERTER

AC OUTPUT
TERMINALS

AC SUBPANEL

FOR UTILITY
BACK-UP AC

LOADS

“PRODUCED”

METER

AC LOADS

TO BE

BACKED UP

120 VAC ONLY

FUSED

DISCONNECT

60A/120 VAC

(OPTIONAL)

CONTROLLER

AC DISCONNECT

(LOCKABLE)

kWh METER WITH

DETENTS (ONE-

WAY)

120 VAC

“PRODUCED”

METER

NEXT TO THE

INVERTER

#6 AWG

REQUIRED

Advertising