Servicing instructions, Servicing requirements/ fault finding charts, Ignition functional chec k 1 – Yeoman EXE MIDI PR1145 User Manual

Page 15: Servicing requirements

Advertising
background image

15

IGNITION

FUNCTIONAL

CHEC

k

1

PILOT

WILL

NOT

LIGHT

Ensure

there

is

no

debris

around

the

pilot

assembly,

(e.g.

soot,

etc.)

which

could

short

the

spark,

clean

the

area.

Operate

the

valve.

Is

there

a

spark?

Consult

Section

2

and

retry.

Check

alignment

of

pilot

burner

head,

change

the

ignition

lead,

see

Diagram

1

on

page

14.

Check

isolation

tap

and

gas

meter,

retry.

Correct

and

retry.

Purge

the

gas

pipes

and

retry.

SEE

'NO

SPAR

k'

CHART

SYSTEM

O

k

There

is

a

blockage

in

the

system,

check

the

inlet

test

point,

the

mag

seating,

valve

and

pilot

filter.

Is

the

gas

turned

on

to

the

appliance?

Is

the

gas

pressure

correct?

Has

the

system

got

any

air

in

it?

Does

the

pilot

light?

Is

the

control

being

operated

correctly?

Will

the

pilot

light

with

a

match?

No

Yes

No

Yes

No

Yes

Yes

No

No

Yes

No

No

Yes

Yes

SERVICING INSTRUCTIONS

SERVICING REQUIREMENTS/ FAULT FINDING CHARTS

1. SERVICING REQUIREMENTS

IMPORTANT – The glass panel on this appliance should

be checked for any signs of damage on the front face of

the glass panel (scratches, scores, cracks or other surface

defects). If damage is observed, the glass panel must be

replaced and the appliance must not be used until a

replacement is installed. Under no circumstances should

the appliance be used if any damage is observed. Please

isolate the appliance until a replacement glass panel has

been obtained and installed. Replacement glass panels

can be purchased from Gazco via the retailer from which

the appliance was purchased or any other Gazco

distributor.

This appliance must be serviced at least once a year by a

competent person. All tests must be serviced by best

practice as described by the current Gas Safe

recommendations.

1.1 Before any test are undertaken on the appliance, conduct a

gas soundness test for the property to ensure that there are

no gas leaks prior to starting work.

1.2 Before any tests are undertaken on the appliance it is also

recommended to fully check the operation of the appliance.

1.3 Special checks:

Clean any lint or fluff from the pilot - pay particular

attention to the aeration hole in the side of the pilot.

Clean away any fluff or lint from under the burner.

Check that the spark gap on the pilot is correct.

1.4 Correct any faults found during the initial tests and then

re-commission the appliance conducting the usual safety

checks.

1.5 Advise the customer of any remedial action taken.

AR0097

3.5mm

15mm

Advertising