9. GAzCO FLUE SURE SYSTEM

9.1 Open the door and remove the ceramics, placing them

carefully to one side. Undo the two screws in the back of

the firebox and carefully withdraw the bracket (see Diagram

14).

AR1442

14

9.2 Disconnect the two sender wires. Undo the two taptite

screws and remove the sensor and the two plastic spacers

(see Diagram 15).

AR1446

15

9.3 Refit the new sensor ensuring that the plastic spacers are

located between the bracket and the sensor. Refit the leads

(see Diagram 16).

AR1452

16

9.4 Feed the cable back through the hole as you replace the

bracket. When the bracket is located correctly it will sit

flush with the back panel without force being required. If

not positioned correctly the bracket will sit at an angle (see

Diagram 17).

AR1448

AR1447

17

10. PRIMARY AERATION PLATE

10.1 Remove the cover plate from the bottom of the stove by

undoing the 6mm bolt (see Diagram 18).

AR1449

18

10.2 Undo the M5 nyloc nut from the bottom of the burner unit

and remove the aeration plate (see Diagram 19).

AR1441

19

10.3 Reassemble in reverse order with the correct aeration plate.