Installation instructions, Technical specification, Covering the following models: yeoman exe midi – Yeoman EXE MIDI PR1145 User Manual

Page 9: Packing checklist

Advertising
background image

9

INSTALLATION INSTRUCTIONS

TECHNICAL SPECIFICATION

Covering the following models:

Yeoman Exe Midi

YM-N9171FL / YM-N9171LC

YM-P9171FL / YM-P9171LC

1 x Stove
1 x Flue infill plate
1 x Front coal
1 x Flame baffle
1 x Coal set
1 x Rear ceramic
1 x Fixing kit containing:
1 x Instruction manual
2 x Wood screws
2 x Wall plugs
1 x Hexagon key

Model

Gas

CAT.

Gas

Type

Working

Pressure

NOX

Class

Aeration

Injector

Gas Rate

m³/h

Input kW

(Gross)

Country

High

Low

Yeoman Exe Midi

YM-N9171FL/LC

I

2H

Natural Gas

G20

20 mbar

5

1 x 7.5mm

260

0.435

4.6

Gross

2.5

Gross

GB, IE

Yeoman Exe Midi

YM-P9171FL/LC

I

3P

LPG Propane

G31

37 mbar

5

1 x 13.5mm

110

0.170

4.4

Gross

2.3

Gross

GB, IE

Efficiency Class II

Flue Outlet Size 127mm (5") ø

Gas Inlet Connection Size 8mm ø

Minimum flue specification T260 / N2 / O / D / 1
Maximum flue temperature 180°C

PACkING CHECkLIST

AR2377

Flat Top 551

Canopy 543

Flat Top 329

Canopy 669

Flat Top 540

Canopy 337

356

371

Canopy 114
Flat Top 107

Advertising