18

3.3 The pilot unit can now be removed by undoing the two

screws (see Diagram 6).

AR1445

6

3.4 Reassemble in reverse order, do not overtighten.

NOTE: SPECIAL CARE SHOULD BE TAkEN WHEN

REPLACING THE THERMOCOUPLE TO THE BACk OF

THE GAS VALVE TO ENSURE THAT THE SENSOR WIRES

FOR THE GAzCO FLUE SURE SYSTEM ARE NOT

DISCONNECTED.

4. IGNITION LEAD AND PIEzO

4.1 Gain access to the back of the pilot assembly (see Section 2)

and disconnect the ignition lead from the electrode.

4.2 Remove the front cover from the control valve (see

Diagrams 7 and 8) and disconnect the other end of the

ignition lead from the valve body. Note the existing route of

the ignition lead.

7

AR0915

8

AR0916

4.3 Replace with a new ignition lead following the same route

as the old one. Replace the valve cover and the pilot

assembly.

4.4 Check operation of the new ignition lead.

5. PIEzO

The piezo assembly used on this appliance is not

serviceable and is unlikely to fail.

6. GAS VALVE

6.1 Turn the gas supply off at the isolation device.

6.2 Disconnect the 2 x 8mm and 1 x 4mm gas pipe fittings at

the back of the gas valve (see Diagram 9, A) and disconnect

the thermocouple (see Diagram 9, B).

9

AR0943

A

C

C

B