Communications port, Power – Zebra Technologies Mobile Printer User Manual

Page 30

Advertising
background image

O-30

Cameo 2/3 Series User Guide

8

7

6

4

2

1

5

3

Communications Port

Pin

Pin

Signal

Signal

Number

Name

Type

Description

1

RXD

input

Receive Data

2

TXD

output

Transmit Data

3

CTS

input

Clear To Send from host

4

RTS

output

Request To Send

set high when printer is

ready to accept command/

data

5

GND

Ground

6

NC

No Connect

7

DSR

input

Data Set Ready: Low to high

transition turns printer on,

High to low transition turns

printer off (if enabled)

8

DTR

output

Data Terminal Ready

high when printer is on (set at

battery voltage for “S” option)

Power

Cameos utilize removable NiMH battery packs. If not connected to a
terminal with DTR present, the Cameo will automatically power off to
conserve battery life. The time-out value can be programmed from
the host terminal; the factory default time-out is two minutes.
Additional power features include:

• Low battery indicated by flashing LED and reported to terminal on demand
• Power On/Off controlled from terminal or keypad

Communications Port (8 pin Circular DIN)

Advertising