The Temperature Limit of Start option can only be set if the FAN x Mode Setting option is set to Automatic Mode. Use the
Temperature Limit of Start option to select the CPU temperature at which the cooling fan should automatically turn on. When
the fan starts, it rotates using the starting pulse width modulation (PWM) specified in the Fan Start PWM option. To select a
value, select the Temperature Limit of Start option and enter a decimal number between 000 and 127. The temperature range is
specified below.

Minimum Value: 0°C

Maximum Value: 127°C

Temperature Limit of Full [080]

WARNING: Setting this value too high may cause the system to become too hot and cause irreparable damage to the system.

The Temperature Limit of Full option can only be set if the FAN x Mode Setting option is set to Automatic Mode. Use the
Temperature Limit of Full option to select the CPU temperature at which the cooling will reach full speed. To select a value,
select the Temperature Limit of Full option and enter a decimal number between 000 and 127. The temperature range is speci-
fied below.

Minimum Value: 0°C

Maximum Value: 127°C

Fan Start PWM [070]

The Fan Start PWM option can only be set if the FAN x Mode Setting option is set to Automatic Mode. Use the Fan Start
PWM option to select the PWM the fan starts to rotate with after the temperature specified in the Temperature 3 Limit of
Start is exceeded. To select a value, select the Fan Start PWM option and enter a decimal number between 000 and 127. The
temperature range is specified below.

PWM Minimum Mode: 0

PWM Maximum Mode: 127

Slope PWM [4 PWM]

The Slope PWM option can only be set if the FAN x Mode Setting option is set to Automatic Mode. Use the Slope PWM option
to select the linear rate at which the PWM mode increases with respect to an increase in temperature. A list of available
options is shown below:

0 PWM

1 PWM

2 PWM

4 PWM

8 PWM

16 PWM

32 PWM

64 PWM