TASK 25-69-01-810-801

4. Fault Isolation

SUBTASK 25-69-01-810-801

A. Troubleshooting Guidelines

(1)

"Table 3. Troubleshooting Guide" provides the Dongle troubleshooting guidelines for

installation and operational issues.

Table 3. Troubleshooting Guide

SYMPTOM

PROBABLE CAUSE

POSSIBLE SOLUTION

ELT and Remote Switch flash

continuously

Dongly is unable to synchronize

with the ELT

Check the ELT protocol is

programmed with a 24-bit

address protocol

Open or short in wiring

Check continuity between pin 1 of

circular connector and pin 12

Check continuity between pin 2 of

circular connector and pin 9 of the

rectangular connector

Check wiring and connections

continuity and security for short

other pins