25-69-01

Page 35 of 44

JUN 27/12

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

DGL-1, DONGLE (453-4010)

Figure 7. Molex Power and Ground Wires

(9)

Connect the ground to the black, un-terminated wire.

NOTE: Refer to Raychem for specific instructions on the splice use. Alternate splices may be

used if installed in accordance with FAA AC 43.13.1A, Section 445, Splices in

Electrical Wire.

(a)

A Raychem solder sleeve splice (Raychem P/N D-1744-01) is provided for this

connection.

(b)

For installations of a ELT/Dongle, splice the black wire to an aircraft ground point near

the ELT. See "Figure 8. Dongle Wiring Diagram".

NOTE: Pin 11 will not be available for remote switch grounding with the Dongle/ELT

installation. Slice a ground for the remote switch .

(c)

For Dongle installations on previously installed ELT, ground the un-terminated ground

wire from the remote switch as described above.

(10) Feed the black circular connector through the rectangular hole in the ELT end cap.

(11) Connect the black circular connector to the plug on the Dongle.

RED

TO 28 VDC

BLACK
TO GROUND