Specifications, A. environmental and physical, Table 2 environmental and physical specifications – ACR&Artex ME406 HM User Manual

Page 28

Advertising
background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406 (453-6603), ME406HM (453-6604)

25-62-30

Page 28 of 84

Jun 25/13

TASK 25-62-30-870-803

3. Specifications

SUBTASK 25-62-30-870-001

A. Environmental and Physical

(1)

Table 2 lists the environmental and physical specifications of the ME406 Series ELT.

NOTE: For automatic activation, the higher threshold of 4.5 ft/sec (2.3

g

) is specified in

accordance with Eurocae ED-62. Use of the higher threshold crash sensor has been

approved by the FAA as a deviation to TSO C126 (FAA Reference #98-130S-108,

February 6, 1998).

Table 2 Environmental and Physical Specifications

CRITERIA

PARAMETER

CHARACTERISTIC

Temperature

Storage

-55° C to +85° C

Operating

-20° C to +55° C

Mechanical

Vibration

10

g

, 5 Hz to 2,000 Hz

Shock

500

g

for 4 ms

Crashworthiness

100

g

for 23 ms

Humidity

95% for 50 hours

Penetration

55 lbs from 6 in. (25 kg from 15 cm)

Crush

1,000 lbs (454 kg)

Altitude

55,000 ft (16,764 m)

Automatic Activation

ME406 Series

(Primary G-Switch)

4.5 ±0.5 ft/sec (2.3

g

)

ME406HM

(Auxiliary Five G-Switches)

12

g

Weight

ELT Complete w/Battery Pack, and

Mounting Tray

1.95 lbs (0.8 kg)

Dimensions (L x W x H)

ELT Complete w/Battery Pack, and

Mounting Tray

6.60 x 3.69 x 2.86 in.

(168 x 94 x 73 mm)

Software

In accordance with RTCA/DO-178B, Level D

Advertising