Figure 21 d-sub plug assembly, D. cockpit remote switch 9-pin plug installation, E. wiring installation – ACR&Artex ME406 HM User Manual

Page 64: G. see figure 21 d-sub

Advertising
background image

ARTEX PRODUCTS / ACR ELECTRONICS, INC

DESCRIPTION, OPERATION, INSTALLATION AND MAINTENANCE MANUAL

ME406 (453-6603), ME406HM (453-6604)

25-62-30

Page 64 of 84

Jun 25/13

(12) Install the strain relief clamp.

Figure 21 D-Sub Plug Assembly

SUBTASK 25-62-30-450-003

D. Cockpit Remote Switch 9-Pin Plug Installation

NOTE: If moisture intrusion is a possibility, apply a thin bead of RTV over rear of the MOLEX

connector to prevent corrosion buildup. Use Dow Corning RTV-3145 or equivalent.

(1)

Insert the wiring pins in the Molex 9-pin cockpit remote switch plug (151-5009), referring to

the wiring diagram appropriate for the installation, as follows:

(a)

Insert each harness female pin into the plug, referring to the wire identification and pin

relationships recorded in Step C.(5)(a).

NOTE: Terminal pins may be removed from the plug using Molex extraction tool

11030002, or equivalent.

(b)

Insert the remote switch power wire female pin into Pin 1 or Pin 3 of the plug, as

appropriate for the selected 14V or 28V power source.

(c)

Insert the remote switch ground wire into Pin 9 of the plug.

SUBTASK 25-62-30-450-004

E.

Wiring Installation

(1)

Route the remote switch harness wire bundle and breakout wiring through the airframe.

GROMMET

(RAISED COLLAR END)

4 OR 5-CONDUCTOR CABLE
(HORN CONDUCTOR NOT
SHOWN)

THUMBSCREW (TYP.)

BRACKET WASHER (TYP.)

HOUSING HALF (TYP.)

HARDWARE (TYP.)

15-PIN

D-SUB PLUG

NOTE: STRAIN RELIEF
CLAMP NOT SHOWN

Advertising